- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- RS485 flow meter
RS485 flow meters
Volumetric flow rate: 4, 2.5, 1.6 m³/h
Process temperature: -40, -10 °C
Process pressure: 0.5 Pa
The RDK STS Keypad Prepaid Gas meter is an unique residential gas meter designed to accurately measure volumes of natural gas. town gas liquefied Petroleum gas etc. With this type you are assured of continuously ...
Process temperature: -40 °C - 150 °C
Ultrasonic-Clamp-on Flowmeter DUC Measuring range: 0- 30 m/s liquid Measuring units: volume flow, flow velocity, thermal output Connection: Clamp-on for pipe sizes DN10...DN6000 Max.temperature: ...
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 12 bar
Precision: 5 %
... which allows the liquid flow meter to be combined with several interface cables, ensures an optimal match and simplifies the integration of a liquid flow meter into a ...
Sensirion
Volumetric flow rate: 0 l/min - 10 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 5 bar
... stability The Axetris mass flow meter OEM-module (MFM) offers outstanding value to the customer. Platinum-based MEMS chip technology guarantees excellent stability and repeatability over the whole ...
Axetris AG
Volumetric flow rate: 2.5 l/h - 180,000 l/h
Process temperature: -50 °C - 300 °C
Process pressure: 40, 16 bar
Suitable for industrial processes of water treatment, heating and cooling circuits, saturated steam circuits, nuclear and thermal plants, treatment ovens, control of gas burners, chemical and petrochemical industry, paper industry, food ...
Process temperature: -40 °C - 130 °C
Precision: 1 %
Repeatibility: 0.15 %
... other meter technologies, such as magnetive inductive meters, can increase so dramatically in the low flow range, that they are unsuitable for monitoring minimum night flows. ...
FLEXIM Flexible Industriemesstechnik GmbH
Process temperature: -25 °C - 250 °C
Process pressure: 1 MPa - 4 MPa
Precision: 0.5, 1 %
... by convertor, you can see the instantaneous flow, cumulative flow, output pulse, analog current and other signals for the measurement and control of fluid flow. It is suitable for the ...
Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ)
Volumetric flow rate: 5 m³/h - 6,500 m³/h
Process pressure: 16, 25, 40 bar
... Turbine Gas Flowmeter Overview HWQZ series intelligent turbine gas flowmeter integrates turbine gas flow sensor and high-performance volume corrector, directly detecting and displaying ...
SHAANXI AEROSPACE POWER HI-TECH CO.,LTD
Process temperature: 0 °C - 50 °C
Process pressure: 0.2 bar - 11 bar
Precision: 0.5, 1, 0.3 %
Reliable technology and industry standard interfaces make the red-y smart series thermal mass flow meters (MFM) and mass flow controllers (MFC) particularly suitable for measurement and ...
CDI 5400 flowmeters make localized metering of air usage a practical way to manage a compressed-air system. Thermal-dispersion mass-flow technology gives the meter sensitivity to low ...
Process temperature: -10 °C - 120 °C
Process pressure: 1.6, 0.6 MPa
Precision: 0.5 %
... proportion to flow speed v: Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow speed in cross-section of measuring tube D-Inner ...
Supmea Automation
Process temperature: -70 °C - 380 °C
Precision: 1 %
... interface of the large graphical display is easy to use even by inexperienced users. With the new quick setup option, your flow measurement can be set up in less than a minute. Online help-texts make the use of the printed ...
systec Controls
Volumetric flow rate: 0 m³/h - 7.9 m³/h
Process temperature: 0 °C - 90 °C
Process pressure: 16 bar
... in the meter reading moment supply low voltage. Meter reading zero error. ● Communication distance between meter and meter reading device: ≤1000m ● Intelligent electronic ...
Shandong Hetong Information Technology Co.,Ltd.
Process temperature: -20 °C - 60 °C
Process pressure: 0.25 bar - 4 bar
... companies for remote copying, monitoring, and control of industrial and commercial gas meter users, and to perform statistical analysis of gas meter gas consumption and meter status. ...
HANGZHOU INNOVER TECHNOLOGY CO., LTD.
Process temperature: -40 °C - 70 °C
Process pressure: 10, 20, 16, 34, 51 bar
Precision: 0.5, 1.5, 0.2, 1 %
... mass flow. Unlike differential pressure (dP) meters that measure volumetric flow, it’s simpler to make and maintain, and no temperature or pressure corrections are required. dP requires ...
Sierra Instruments
Process temperature: -40 °C - 160 °C
Precision: 1, 1.5, 0.5, 0.2 %
... transit-time ultrasonic flowmeter with clamp-on sensors for non-invasive liquid measurement. Based on microprocessor and programmable flow measurement techniques the process flow can ...
ALIA GROUP INC
The FLODEM electromagnetic flow meters are based our decades of experience. They've are highly reliable, easy to operate and very suitable for harsh conditions.
SMAAT TECHNIQUES SAS
Process temperature: -40 °C - 85 °C
... for Outdoor Applications 1500 N Tensile Strength Kevlar Reinforced Cable Surge Protection for Power and RS485 Communication RS485 Digital Communication, Minimize ...
Process temperature: -10 °C - 100 °C
Process pressure: 0.2 MPa
Precision: 2.5 %
... Customized air velocity range 1... 30 m/sec Temperature -20 ... 65°C Humidity 0... 100%RH Fast response time 10 msec 2 RS485 Modbus or I C for easy networking Easy installation Applications ...
SIARGO
Process temperature: -40 °C - 160 °C
Precision: 1 %
Series DUS-TT-F wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art ...
Prisma Instruments
Process temperature: -20 °C - 50 °C
... apart in the direction of flow. High efficiency air curtains are fitted to considerably extend the time between maintenance periods and window cleaning (typically 1 year). Features & Benefits Non-contact infra-red sensing. Continuous ...
Codel International
Volumetric flow rate: 0.2 m³/s - 20 m³/s
Process temperature: -25 °C - 70 °C
Process pressure: 20 bar
Product of Taiwan, Non invasive design, no down time for installation, no pipe cutting, maintenance at any time, significantly reduce installation and maintenance costs. Tube installation-zero tube damage, no blockage, no leakage and ...
Process temperature: -40 °C - 260 °C
Process pressure: 40 bar
Precision: 0.75, 1, 0.85, 1.5 %
Vortex flow meter in order to adapt to different caliber and scene is divided into: clamping vortex flow meter, insertion vortex flow meter, ...
Hangzhou ARTang Intelligent Equipment Co., Ltd
Process temperature: -20 °C - 60 °C
Precision: 0.5 %
MAGE1 is an economic flowmeter with a carbon steel sensor and plastic transmitter that satisfies standard customer requirements. It is mains powered flowmeter (9-35 VDC) with 4-20 mA output, RS485 ...
Arkon Flow Systems
Volumetric flow rate: 0 l/min - 100 l/min
Process temperature: -10 °C - 55 °C
Process pressure: 0.8 MPa
YUNYI Air flow meters,MF5700 digital air gas mass flow meter are specifically designed to meet the needs of applications that require separation of display and body. ...
Xi'an Yunyi Instrument Co., Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining