- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- RS485 flow meter
RS485 flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Mass flow rate: 0 kg/h - 2,200,000 kg/h
Process temperature: -196 °C - 240 °C
Process pressure: 100 bar
... process safety – immune to fluctuating and harsh environments Fewer process measuring points – multivariable measurement (flow, density, temperature) Space-saving installation – no in-/outlet run needs Full access ...
Endress+Hauser AG

Process temperature: -10 °C - 40 °C
... integrated, good looking appearance. Built-in industrial lithium battery. Low-flow measurement function available All-in-one detect probe, measure flow velocity, temperature, presure and ...
Cubic Sensor and Instrument Co.,Ltd

Process temperature: -40 °C - 60 °C
... gas flow meter is an advanced electronic meter for natural gas flow measurement, which adopts ultrasonic technology to maintain long-term accuracy without degradation. With ...
Cubic Sensor and Instrument Co.,Ltd

Process temperature: -20 °C - 60 °C
... flue duct. This flowmeter adopts the non-contact measurement method, which can effectively solve the measurement difficulties such as unstable flow field and uneven flow velocity distribution ...
Cubic Sensor and Instrument Co.,Ltd

Mass flow rate: 0 kg/h - 860,000 kg/h
Process temperature: -50 °C - 205 °C
... series of compact system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs. With ...

Mass flow rate: 0 kg/h - 250,000 kg/h
Process temperature: -50 °C - 205 °C
CoriolisMaster FCH100 series of compact hygienic system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus ...

Mass flow rate: 0 kg/h - 0.16 kg/h
Volumetric flow rate: 0 m³/s - 0 m³/s
Process temperature: 0 °C - 50 °C
... OLED display Digital or analog output; alarm and counter functions Features Clear indication in: - actual flow rate (bar graph and value) - desired flow units - type of gas - ...
Mass Flow ONLINE BV

Mass flow rate: 0 kg/h - 1.55 kg/h
Volumetric flow rate: 0 m³/s - 0.0003 m³/s
Process temperature: 0 °C - 50 °C
... OLED display Digital or analog output; alarm and counter functions Features Clear indication in: - actual flow rate (bar graph and value) - desired flow units - type of gas - ...
Mass Flow ONLINE BV

Mass flow rate: 0 kg/h - 15.5 kg/h
Volumetric flow rate: 0 m³/s - 0.0033 m³/s
Process temperature: 0 °C - 50 °C
... OLED display Digital or analog output; alarm and counter functions Features Clear indication in: - actual flow rate (bar graph and value) - desired flow units - type of gas - ...
Mass Flow ONLINE BV

Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring ...
Pulsar Measurement

Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer ...
Pulsar Measurement

Process temperature: -20 °C - 50 °C
... applications. Area-Velocity Measurement / Open Channel Flow Measurement with No Primary Measuring Device FlowCERT can be combined with a MicroFlow for velocity measurement. Or for area-velocity flow ...
Pulsar Measurement

Volumetric flow rate: 0 m³/h - 33,629 m³/h
Process temperature: -200 °C - 350 °C
... U-shaped dual sensors maximize accuracy Flow rate turndown up to 200:1 Suitable for liquids and gases Sensor sizes from <1mm through 10” Ability to measure rates from 0-0.032 GPH to 0-423,000 BPD Flow ...

Process temperature: -200 °C - 427 °C
Process pressure: 150 psi - 1,500 psi
Precision: 0.7, 2, 1.3, 1.2, 1.6 %
... included in every meter simplifies electronics verification All meters arrive pre-configured and hydrostatically tested, making them ready and easy to install Simplify SIS compliance with available ...
Emerson Automation Solutions - ROSEMOUNT

Volumetric flow rate: 0.1 l/min - 100 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 10, 64, 100 bar
... EL-FLOW® Prestige, the latest generation thermal mass flow meters and controllers for gases, represents a truly ground-breaking shift in versatility and user-friendliness. Its principal ...

Volumetric flow rate: 0.2 l/min - 5 l/min
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 10 bar
... has developed the IQ+FLOW® mass flow sensor. Due to the use of micro solid state technology (MEMS), Bronkhorst has been able to halve the footprint dimension to 0.75", thereby realizing the ultra compact ...

Volumetric flow rate: 0.4 l/min - 25,400 l/min
Process temperature: 0 °C - 50 °C
Precision: 1.5 %
... Display of Flow Rate and Total • 4 to 20 mA Re-transmission of Flow Rate (DIN 50 and smaller sizes only) • RS485 Communications (Modbus®) • For Most Clean ...

Volumetric flow rate: 0.2 m³/h - 848.2 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... of the EE741 flow meter is optimised for easy installation and maintenance. Once the gauge mounting block is installed in the pipeline, the transmitter can be installed and removed without any pipework. ...

Volumetric flow rate: 1.7 m³/h - 263,350 m³/h
Process pressure: 0 bar - 16 bar
Insertion mass flow meter for DN50 - DN700 (2" - 28") and up to 16 bar (232 psi) The EE776 is a thermal mass flow meter dedicated for monitoring compressed air, nitrogen, ...

Process temperature: -20 °C - 480 °C
Process pressure: -10,000 Pa - 10,000 Pa
... flue duct. This flowmeter adopts the non-contact measurement method, which can effectively solve the measurement difficulties such as unstable flow field and uneven flow velocity distribution ...

... respectively. The gas flow rate in the flue is calculated through the time difference of ultrasonic wave transmission, and the volume flow rate of the flue gas is calculated according to the cross-sectional ...

Volumetric flow rate: 3 m³/h - 3,200 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
... supply: Safety Barrier Ui=5V, Li=100mA (main power supply) Internal battery: 3.6V ER26500(backup power supply) Communication: RS-485 Explosion-proof level: ExibllAT4Gb IP grade: IP65 Applications • ...

Process temperature: -20 °C - 80 °C
Precision: 1.5 %
... ultrasonic flowmeter M-Flow PW This ultrasonic portable flowmeter consists of a detector clamped on the pipe (DN25 to 1200 mm depending on detectors) and of a and of a digital converter ...

Process temperature: -15 °C - 85 °C
ULTRASONIC COMPACT INTEGRATED FLOWMETER S-FLOW – FSZ A PRECISE AND COMPACT SOLUTION FOR FLOW MEASUREMENT The S-Flow – FSZ ultrasonic flowmeter is ...

Volumetric flow rate: 0 m³/h - 120 m³/h
Process temperature: -30 °C - 180 °C
Process pressure: 16 bar
... external (sanitary) meters and optional analogue and RS485 output for measuring cold water or pre-programming the value for open systems. Description The energy meter ...

... ultrasonic technology for mobile and highly accurate flow measurements Special features: ■ Very high measurement accuracy (also bidirectional) ■ Accurate even at extremely low flow rates (e.g. minimum ...

Volumetric flow rate: 0 l/min - 500 l/min
Process temperature: -20 °C - 70 °C
Process pressure: 15 bar
... performance and high range ability Gas Flow Meters. Description The CMS series of gas mass flow meters employs our proprietary thermal flow rate sensor ...

Volumetric flow rate: 0 l/min - 20 l/min
... analog output as well as Modbus RS232/RS485 or I2C. Fully customized variants are also available on request. Measuring range [SCCM] 0 to 0.1...20 SLPM or 0 to ±0.1...±20 SLPM Output ...

Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 10 bar
Precision: 0.35, 1 %
One device. Multiple gases and flows. Maximum flexibility. Multiple gases in one device equals maximum process flexibility and productivity. The GF40 Series elastomer sealed mass flow controllers and ...
Brooks Instrument

Volumetric flow rate: 0 l/min - 300 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 34.47 bar
... controllers and meters provides. Designed for semiconductor, MOCVD and other gas flow control applications, the GF100 series exceeds the semiconductor industry standard for reliability, ...
Brooks Instrument

Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 10.34 bar
Precision: 0.35, 1 %
... levels of purity—that’s the performance the GF100 series of metal sealed mass flow controllers and meters provides. Designed for semiconductor, MOCVD and other gas flow control ...
Brooks Instrument

Process temperature: -45 °C - 454 °C
Process pressure: 6.9, 34, 70, 10 bar
Precision: 1.75, 0.5 %
... thermal flow meters are your solution for large diameter pipe and air ducts applications. Applications Combustion air Stack gas flow Primary, secondary and overfire air flow Preheater ...

Process temperature: -20 °C - 50 °C
... 15 universal inputs max. 72 analogue inputs max. 72 digital inputs max. 36 TC inputs max. 18 RTD inputs max. 12 counter / flowmeter / ratemeter inputs max. mixed: analogue-NTC temperature mixed: ...

Process temperature: -20 °C - 50 °C
... maximum speed 10Hz (ten samples per second) 4 GB internal data memory RS-485 (Modbus RTU), USB Host, Ethernet communication panel, compact device in 96 x 96 mm case The MultiCon CMC-99 ...

Process temperature: -20 °C - 50 °C
MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package stable firmware based on Linux 13 available input/output blocks colour LCD display 3,5" TFT, with touchscreen recording data with maximum speed ...

Volumetric flow rate: 0 m³/h - 244,290.2 m³/h
Process temperature: -20 °C - 120 °C
Process pressure: 1.6, 1, 0.6 MPa
The NMG-Series electromagnetic flowmeter is used to measure the volume flow of conductive liquids and slurries in closed pipes. The measuring flow rate is not affected by density, viscosity, ...

Volumetric flow rate: 0 l/min - 10,000 l/min
Precision: 0.2, 0.5 %
Repeatibility: 0.15 %
... Analog and Digital Output 0-5VDC, 0-10VDC, 4-20mA RS232, RS485, USB Flow ...

Volumetric flow rate: 0 l/min - 2,500 l/min
Process pressure: 0 bar - 34.47 bar
Precision: 0.5, 0.2 %
Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements. HFM-D-306A/HFC-D-308A mass flow instruments have flow ranges from 0-2500 ...

... configurability and local control over the instrument. DIGITAL COMMUNICATIONS. The Digital 300B Sériés is equipped with RS232, RS485 and USB for digital communications. The USB connector ...

Volumetric flow rate: 1.6 m³/h - 3,125 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 1 bar - 10 bar
... reasonably priced, most accurate flow meter tailored for your applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation. EPD ...
FineTek Co., Ltd.

Process temperature: -20 °C - 60 °C
Precision: 2.5 %
... waves are dispersed is proportional to the flow rate of the liquid. Hence, the flow rate of the liquid is derived. EPU Clamp-On Ultrasonic Flowmeter No intrusion in the pipeline ...
FineTek Co., Ltd.

Process temperature: -156 °C - 60 °C
Process pressure: 10 bar
Repeatibility: 0.4 %
... measurement to get real flow signals, Elimination of bearing、Axial friction coefficient error and the leaf blade resistance error etc. Calculate the K value read. The company's flow test equipment, Testable ...
FineTek Co., Ltd.

Process temperature: -20 °C - 70 °C
... ambient conditions. The large graphic display permits quick and easy commissioning of the flow meter system. Due to the modular construction of our radar flow meter ...

Process temperature: 0 °C - 120 °C
Process pressure: 10 bar
... or ducts • No real upper limit of mass flow • Maximum pressure 10 bar • Dust tight • No flow restrictions to the process flow (wear resistant ceramic liner) • The mass flow ...

Process temperature: -40 °C - 150 °C
Precision: 1 %
... Stationary · portable Flow velocities: 0 ... ±30 m/s Measuring units: volume flow, flow velocity, thermal output Connection: clamp-on for pipe sizes DN10 ... DN6000 Output: 2x 4 - ...
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining