DN: 0.25, 0.375, 0.5 in
Pressure: 2 bar - 10 bar
Temperature: -5 °C - 50 °C
... function to maintain the command sequence » Opening of the main seat at about 50% of the inlet pressure Series MC soft start valves are used to avoid damages to people or equipment ...
DN: 0.25, 0.125, 0.375 in
Pressure: 2 bar - 10 bar
Temperature: -5 °C - 50 °C
... or to extend switching time » Additional air intakes with the same characteristics of the outlet air (line) The soft start valves are used to avoid the sudden movement of pneumatic ...
DN: 0.375 in - 1 in
Pressure: 2 bar - 16 bar
Temperature: -5 °C - 60 °C
... reques These soft start valves allow a gradual increase of the pressure in pneumatic systems. The pressure increases slowly according to the set regulation until it reaches half of ...
DN: 0.125 in - 1 in
Pressure: 2.5 bar - 13 bar
Temperature: -5 °C - 50 °C
• Progressive start-up valve • Available in 4 sizes with flow rates up to 15000 Nl/min and connections from 1/8” to 1” • Suitable for downstream system gradual pressurization • Downstream circuit filling ...
Pressure: 10 bar - 17 bar
Temperature: -20 °C - 65 °C
Flow rate: 21 l/s
... to comply with PUWER (Provision and Use of Work Equipment Regulations) Controlled increase of downstream pressure on start up High forward flow capacity High flow dump facility
Pressure: 17, 10, 3 bar
Temperature: -20 °C - 80 °C
Flow rate: 147 l/s
... to comply with PUWER (Provision and Use of Work Equipment Regulations) Controlled increase of downstream pressure on start up High forward flow capacity High flow dump facility
DN: 0.125 in - 1 in
Pressure: 3 bar - 10 bar
Temperature: -10 °C - 50 °C
... bursts. A sophisticated system of internal valves allows two separate stages of operation. During the first stage, a quantity of air that can be regulated via a pin flows from the APR. The second stoge starts ...
Pressure: 15 bar
Temperature: -10 °C - 50 °C
AIRWORK's XA1 series soft start valves with quick exhaust use air, with pressures up to 15 bar, operating temperatures from -10 to 50 °C. Flow rates (6 bar), with ∆p=1 bar: 1,850 Nl/min; ...
DN: 0.25 in - 1 in
Pressure: 3 bar - 10 bar
Temperature: -10 °C - 50 °C
Wall clamping screwsFRL1 M5x18 FRL2 M5x18 FRL3 M6x20 FluidCompressed air. Maximum Pressure 15 bar Assembling positionVertical
DN: 50 mm - 600 mm
Pressure: 25 bar
Flow rate: 16 m³/h - 5,400 m³/h
PUMP CONTROL VALVE The valve isolates pumps from the system during pumps starting and stopping to protect pipe lines and pumps itself. The valve is equipped with a control solenoid ...
DN: 800 mm - 1,400 mm
Pressure: 1 bar - 25 bar
Flow rate: 3,900 m³/h - 23,200 m³/h
The valve shall be made with high hydrodynamics section globe body, without stagnation pockets (conical, low pressure loss type), the main valve body and cover shall be made in standard ductile cast iron ...
DN: 0.25, 0.5 in
Pressure: 0 bar - 16 bar
Temperature: 0 °C - 60 °C
– Robust design – Modular structure Operating pressure - Max. 25 bar, depending on design Materials - Body made of aluminium pressure die-casting Cup made of metal Thread - DIN 2779 Connection sizes - G1/4“ to G1“ Medium - Compressed air
Pressure: 3 bar - 10 bar
Temperature: 0 °C - 50 °C
Flow rate: 2,580 l/min
Gradually pressurizes the system until reaching the set operating pressure value. * Before delivering the maximum available pressure, the air is allowed to slowly flow around the downstream circuit until about 60% of the pressure ...
Aircomp by Stampotecnica
DN: 0.125 in - 0.5 in
Pressure: 35 psi - 130 psi
Temperature: 0 °F - 160 °F
Soft-start valves allow pneumatic components to be pressurized slowly for safety and control. MGV series soft-start valves are available ...
DN: 0.25 in
Pressure: 3 bar - 10 bar
Temperature: -10 °C - 50 °C
... pressure is adjustable via the needle valve in the cover. Note: soft start valves are not intended to be used as emergency shut-off valves, but should ...
Parker Pneumatic Division Europe
DN: 16, 25, 40, 50 mm
Soft start valves are used to throttle the gas flow in roughing lines. They prevent turbulences in piping and containers, particulate contamination in vacuum installations, detachment ...
Special valve that lets the first delivered compressed air escape so that the compressor will start more easily. Is mounted on the non-return valve.
DN: 0.25 in
Pressure: 0 bar - 16 bar
Temperature: -10 °C - 50 °C
Shut - off valves series "UZVL" are produced with connection G1/4" and they are fit to be locked in the exhaust position by means of a standard padlock.
DN: 6.5 mm - 24 mm
Pressure: 10 bar
Temperature: -20 °C - 80 °C
... circuits where a cut-off in pressure, an abrupt start-up is to be avoided to prevent possible damages to equipment. TECHNICAL CHARACTERISTICS Max. working pressure: 10 bar Ambient and fluid temperature: -20 Valve ...
DN: 50, 63 mm
Pressure: 10 bar - 30 bar
Temperature: -20 °C - 65 °C
... from maintenance. Start Systems for Two and Four-Stroke Engines Pilot-operated Valves for Start Valves Pilot-operated Valves for air starters ...
DN: 0.375 in - 0.5 in
Pressure: 145 psi
Temperature: 32 °C - 140 °C
FAV Series soft start valves protect your pneumatic system and give you peace of mind whenever installation or repair occurs. The valves raise incoming pressure, supplying ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining