Primary current: 0.5 A - 500 A
... iron core (closed magnetic circuit). If an alternating current I1 flows through the winding B1, a current I2 is induced in the winding B2, which depends on the winding ...
Consistent, high-precision current testing across a wide temperature range Hioki AC/DC clamp sensors are best-in-class current sensors for use with power ...
Primary current: 1,000 A
... range [A] 1000 Error [ 1 Output signal -4 ~ 4 V Supply voltage [V] 15 Opening form Rectangular Case type Split coreMounting Conductor rail mounted Opening diameter [mm] 6.5 mm,
Angst+Pfister Sensors and Power AG
Primary current: 300 A
... range [A] 300 Error [ 1 Output signal -4 ~ 4 V Supply voltage [V] 15 Opening form Rectangular Case type Split core Mounting Conductor rail mounted Opening diameter [mm] 9.5
Angst+Pfister Sensors and Power AG
Primary current: 600 A
... range [A] 600 Error [ 1 Output signal -4 ~ 4 V Supply voltage [V] 15 Opening form Rectangular Case type Split core Mounting Conductor rail mounted Opening diameter [mm] 9.5
Angst+Pfister Sensors and Power AG
Primary current: 50, 100 A
The sensors in the QI-HSC series measure DC and AC currents with high accuracy and a wide range of measurements. The QI-HSC use the Hall effect measurement technique ...
Primary current: 5 A - 2,500 A
Primary current: 75 A - 1,000 A
SCY15C Series open loop current sensor is develop on basis of Hall effect. It is especially designed for the electronic measurement of DC, AC or pulsed currents in high ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 50 A - 500 A
SCY6D is single power supply current sensor develops on hall-effect principle. Split core type, so the up and down can be open and close without removing ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 2,000, 200 A
... suit for larger primary input current measure. Primary input current range 200A..2000A, primary aperature size ø40mm. Main features: 1. SCY7 Series Hall Current Sensor ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 5 A - 1,300 A
DENT Split Core current transformers are compatible with ELITEpro Series energy data loggers, PowerScout Series power meters, or any meter which accepts a 333mV output ...
DENT INSTRUMENTS
Primary current: 0.1 A - 250 A
TT Compact current transformers Product type - Compact current transformer Secondary current - 1 A Applications - Measurement accessory
Primary current: 50 A - 500 A
... FEATURES •DC, AC current measurements with Galvanic isolation •Split core or Clamp on current sensors •Extended measuring range in ...
Electrohms
Primary current: 50 A - 600 A
Flame résistance: UL94-V0 Working température: -10~+70’C Storage température: -40—+85”C Bandwidth: DC~25kHz Dielectric strength: 2.5KV 50Hz 1min
YHDC Dechang Electric
Primary current: 0 A - 200 A
UL2808 XH-SCT-0750 Split Core Current Transformer CTs Specifications: 1.Rated current:0-200A 2.Rated output:mA or mV(0.333V) 3.Rated Voltage:0.66KV 4.Insulation ...
Jiangyin Spark Electronic Technology Co.,LTD
Primary current: 10 A
... KET-SHA-001.21 is part of a newly developed series of open-loop Hall current sensors that can be used for the detection of DC, AC, even high-frequency, impulse and irregular current ...
Kerberos Srl
Primary current: 500 A
... hall effect current sensor is a open loop device based on the measuring principle of the hall effect , with a galvanic isolation between primary and secondary circuit, it provides accurate electronic ...
Rongtech Industry (Shanghai) Inc.,
Primary current: 50 A - 2,000 A
... external power required. Accurate at very low input current levels (below 1% of full scale) Self powered Split core design Rugged molded plastic housing Connect up to ...
Primary current: 1,000 A
The S29S1T0D24Z is well-suited for extensive power of UPS and purpose inverter. It is equipped with an aperture size of φ38.5. A bipolar power supply of ±24 V is incorporated. It comes with an insulation ...
Primary current: 800 A
... SCT-1250 series is a popular and frequently used split core current sensing transformer. Designed to transform up to 800 amperes of AC input current ...
Manutech Europe
Primary current: 30 A
Current Sensor Features ·UL-Listed ·Output 0.333 Volt AC at rated current ·Operates from 50 Hz to 400 Hz ·Phase displacement < 1.0° at rated current ·Accuracy ...
MAGNELAB
Primary current: 5 A - 630 A
This ultra compact & light-weight hinged split-core current transformer is designed for installation on branch circuits within the electrical panel. This split-core ...
Primary current: 0 A - 2,000 A
Leakage current sensor, specifically for detecting micro current, or differential current in two current wires, the range is between 10mA~10A. The ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining