Voltage: 1 mV - 200,000 mV
... deliver leveled sine waves up to 4 GHz and precisely controlled pulse edges, setting a new standard in calibration performance. Unlike conventional calibrators, the 9500C's Active Head Technology™ allows ...
Fluke Calibration
The Rosemount 8714D Transmitter Calibration Standard ensures traceability to NIST standards and long-term accuracy of the flow meter system. This high-precision instrument can be used to recalibrate Rosemount ...
Application : Calibration System for Bottom Bracket Bearings Technical Details : Calibration of torque sensors in bottom bracket bearings for bikes. Range up to 100 N·m at 150 min-1. Measurement of torque, speed and ...
Temperature: -10 °C - 50 °C
Pressure: 25 mbar - 1,000,000 mbar
Voltage: 4 V
... multifunction calibration tools. Druck multifunction calibrators provide an all-in-one solution for your pressure measurement and generation needs. Our latest DPI 620 Genii multifunction process calibrator ...
Temperature: 10 °C - 50 °C
Pressure: 750 mbar - 1,150 mbar
... PACE Tallis is a compact and robust transfer standard calibrator that is ideal for in-situ testing and interlaboratory comparisons. Engineered to be a versatile offering, PACE Tallis maintains performance ...
Temperature: 100 °C - 1,210 °C
Voltage: 100 V - 240 V
... ADT878-1210 Thermocouple Calibration Furnaces. With an unmatched stability, uniformity and an optional on-board process calibrator, calibrating thermocouples has never been easier. With two separate units to choose ...
Temperature: -25 °C - 1,205 °C
... portable temperature calibrator is a fast, time-saving, reliable dry block temperature calibrator designed for on-site use. The large color display is easy-to-read and provides icons and information regarding ...
Temperature: -10 °C - 400 °C
The ETC Series is the ideal dry block temperature calibrator when time is the critical factor and the highest accuracy is not a requirement. The block heats up to 100°C per minute and stabilizes in just 3 minutes! The ...
Temperature: -250 °C - 1,820 °C
... time. The ASM may be combined with any JofraCal compatible pressure calibrator, dry-block or liquid calibrators, DTI reference thermometers, and ASC multi-function process calibrators. ...
... temperature values. • Computer-aided data processing with all the corrections necessary included. Units - mm / in Standard - ISO 3650 Repeatability - 0,015 μm Measuring range - 25 mm
... data processing with all required correction values included. • Performs calibrations that meet the requirements of both ISO standards and EA guidelines (EAL – European cooperation for Accreditation ...
Temperature: -10 °C - 55 °C
Voltage: 115, 240 V
... cells. In addition, the LCc is pre-configured at the factory to read actual load cell mV/V outputs for use as a measurement standard with virtually any load cell or other Wheatstone bridge based transducer. For portability, ...
Temperature: 0 °C - 40 °C
SCAL2 Handheld AE Calibrator are designed and developed for the requirements of acoustic emission detector calibration. It can export various standard parametric signals like amplitude, rise time, counts ...
Temperature: -196 °C
The BL631 liquid nitrogen comparison calibrator is specially designed to calibrate standard platinum resistance thermometers (SPRT) and other temperature probes in extreme cold temperature. With the ability ...
Temperature: 35 °C - 500 °C
Voltage: 220, 110 V
... embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The ...
Temperature: 35 °C - 500 °C
Voltage: 110, 220 V
... embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The ...
Temperature: -5 °C - 60 °C
... • Integrated FDA 21 CFR part 11 compliant Rotronic HW4 software Since its launch, the Rotronic HygroGen has defined the standard for portable humidity and temperature calibration. Hundreds of users worldwide have identified ...
Temperature: 30 °C - 250 °C
... This gives greater accuracy and traceability meeting the requirements of ISO 9000 and other quality standards. For liquid bath, surface sensor and blackbody use, an external standard ...
Pressure: 0 bar - 2 bar
Voltage: 230 V
... to conduct calibration on: transmitters and temperature and vacuum/pressure converters. These instruments consist of standard signal generators that generates/measures pressure signals, vacuum and simulates signals ...
GIUSSANI SRL
Frequency Laser Standard in new form factor. It is now available in rack mount to make your laboratory ergonomics even better. This automatic laboratory device is designed to calibrate and compare He-Ne (632,8nm wavelength) ...
Temperature: 14 °F - 122 °F
Pressure: 50 psi - 10,000 psi
... seat tightness tests can be performed with precision while generating solid data to back up your observations. Follow standard ASME Section 8 or create your own tests to follow your SOPs. Work in Hazardous Locations ...
M2710 is the new digital portable calibrator of ForTest® M series. Enclosed in a container of anodized aluminium with shatterproof plexiglass front, we find a completely new circuit board and a mass flow meter sensor, ...
Temperature: -25 °C - 60 °C
Voltage: 0 V - 60 V
Single T/C Simulator The PIE 520B Thermocouple Simulator simulates a dedicated standard thermocouple curve over the entire industrial temperature range. The PIE 520B provides precise temperatures for inputs to all ...
PIE - Pratical Instrument Electronics, Inc
Temperature: 50 °C - 500 °C
Pressure: 70,000 Pa - 120,000 Pa
Voltage: 24 V
... Solution reflects the result of decades of experience providing world-class solutions for the process industries. This standardized yet configurable solution is easy to use, versatile, and ergonomic. Modular and versatile CENTRiCAL ...
Beamex
Temperature: -20 °C - 140 °C
Voltage: 110, 120, 220, 240 V
The Tecal 140F is part of a new range of light-weight and portable field Dri-Block calibrators. This model operates from 45°C below ambient (typically -20°C) up to 140°C. All Tecal 140F models are offered with RS-232 ...
Techne Calibration
... calibration. Ensures uniform and reproducible process quality. Force is determined from a conversion table. Covers the entire standard range of closing forces. Provides electronic data exchange in combination with ...
Temperature: 5 °C - 40 °C
Pressure: 20 psi - 40 psi
Voltage: 85 V - 265 V
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration ...
Teledyne API
Temperature: -20 °C - 60 °C
Pressure: 1,000 bar
Voltage: 0 V - 10 V
... output for pressure transmitters USB- and RS232-interface Calibration certificate, traceable to national standard included in scope of standard delivery (for pressure, current and voltage) The reference ...
DRUCK & TEMPERATUR Leitenberger GmbH
Temperature: 10 °C - 30 °C
The SRP-10G0-10T0 calibrator is a source of high resistance, used as a standard in calibration and tests of analogue and digital insulation resistance meters. The setted resistance by the calibrator ...
Sonel SA
... disassemble the heads • Measurement traceability • Data collection reports • Customized change parts can be manufactured TCT standard toolless mechanical interfaces: • Quick release male/female adapters for Zalkin ...
Temperature: -196 °C - 420 °C
Voltage: 9 V
Ellab Temperature Standard ETS10 The traceable ETS allows for extremely accurate temperature measurements by converting resistance into temperature using its built-in algorithms. When connected to the ValSuite software, the ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining