Level range: 0.4 m - 120 m
Process pressure: -1 bar - 40 bar
Process temperature: -55 °C - 1,200 °C
RADAR SENSOR The multifunctional 80 GHz radar sensor, available in two-wire and four-wire technology, provides continuous, non-contact level measurement for bulk solids and works very ...
UWT GmbH
Level range: 250 mm - 120,000 mm
Process pressure: -1 bar - 160 bar
Process temperature: -196 °C - 450 °C
RADAR SENSOR The multifunctional 80 GHz radar sensor, available in two-wire and four-wire technology, provides continuous, non-contact level measurement for liquids and works very precisely, ...
UWT GmbH
Level range: 160 mm - 4,000 mm
Process pressure: -1 bar - 16 bar
Process temperature: -40 °C - 150 °C
Level detection with vibration rod Mononivo® single-rod limit switches for point level measurement are suitable for many applications within the bulk material handling industry as a full, demand or ...
UWT GmbH
Level range: 200 mm - 3,000 mm
... all common process connections and sensor lengths For hygienic and industrial applications For any conductive media, whether foaming, pasty or adhering homogeneous - with conductivity > 5 µS/cm Automated sensor ...
Level range: 10 m
Process pressure: 8 bar
Process temperature: -40 °C - 80 °C
... maintenance-free operation * Remote sensor parameter setting and level monitoring via connection to the IT system Trouble-free monitoring of large tanks With the LW2720 level ...
ifm electronic
Process pressure: 0 bar - 1 bar
Process temperature: -10 °C - 85 °C
Low-cost, simple level measurement Pressure compensation via internally vented cable Reduced wiring complexity due to two-wire current loop High overall accuracy and long-term stability Versions with ...
ifm electronic
Level range: 25 mm - 636 mm
... and switch-off points with window function Units with scalable analogue output and additional overflow alarm Clearly visible LED display Level and temperature monitoring with just one unit ...
ifm electronic
Level range: 50 mm - 35,000 mm
Process pressure: 0 bar - 40 bar
Process temperature: -40 °C - 130 °C
... is a non-contact radar level meter for continuous level measurement. The unit is available in two variants: ● with thread and horn antenna (ø 40 mm). Particularly suitable for use in small tanks ...
Process pressure: 100 bar
Process temperature: -40 °C - 115 °C
The BLS Trimod´Besta Level Sensor is universally suitable for level detection and a real alternative to the tuning fork. It works in liquids of all kind, foams, bulk goods, granulates, ...
Process pressure: 0 bar - 6 bar
Process temperature: -40 °C - 80 °C
... the submersible pressure sensor is perfectly suited for the measurement of liquid levels, also in the outdoor area. Applications Level measurement in vessel and storage ...
Level range: 0 m - 120 m
Process pressure: -1 bar - 160 bar
Process temperature: -196 °C - 450 °C
... a radar sensor for continuous level measurement of liquids and bulk solids. The small process fittings offer particular advantages for liquids in small tanks or tight mounting spaces. ...
VEGA Grieshaber KG
Level range: 0 m - 8 m
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 60 °C
... the ideal radar sensor for non-contact level measurement in all standard applications where a high degree of protection is required. It is particularly suitable for level measurement ...
VEGA Grieshaber KG
Level range: 0 m - 15 m
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 80 °C
... VEGAPULS 21 is the ideal radar sensor for non-contact level measurement in standard applications in all industrial plants. It is particularly suitable for level measurement ...
VEGA Grieshaber KG
Level range: 0 m - 15 m
Process pressure: 0 bar - 3 bar
Process temperature: -40 °C - 80 °C
... radar sensor for continuous level measurement Application area Axial cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex-approval VEGAPULS C ...
VEGA TECHNIQUE
Level range: 0 m - 15 m
Process pressure: 0 bar - 3 bar
Process temperature: -40 °C - 80 °C
Wired radar sensor for continuous level measurement Lateral cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex approval VEGAPULS C 22 is the ...
VEGA TECHNIQUE
Level range: 0 m - 8 m
Process pressure: 0 bar - 3 bar
Process temperature: -40 °C - 60 °C
... non-contact level measurement in simple applications. It is particularly suitable for use in water treatment, storage tanks with acids, lyes and additives in all industrial areas, or ...
VEGA TECHNIQUE
Level range: 62 in - 866 in
Process temperature: -40 °F - 221 °F
The Level Plus® Tank Slayer® liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility ...
Temposonics
Level range: 12 in - 300 in
Process temperature: -40 °F - 221 °F
The Level Plus® RefineME® liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process ...
Temposonics
Level range: 12 in - 300 in
Process temperature: -40 °F - 221 °F
The Level Plus® SoClean® liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process ...
Temposonics
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
The IMP range of level sensors feature a combined transducer and controller in one self-contained unit. All IMP units from Pulsar Measurement are non-contacting, accurate, and reliable level ...
Pulsar Measurement
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
... non-contacting level sensors are suitable for tank level measurement, water and wastewater applications, stock control, tank volume conversions, industrial ...
Pulsar Measurement
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
... applications, industrial level measurement, tank level measurement, stock control, and health and safety compliance. To find out more about the IMP range of level measurement ...
Pulsar Measurement
Level range: 0.3 m - 10 m
Process pressure: 0 bar - 6 bar
Process temperature: 1 °C - 50 °C
... ultrasonic interface sensor for: Wastewater treatment plants: - Solid sedimentation measurement Drinking and process water: - Solid sedimentation measurement - Filter monitoring and filter backwash - Level ...
Endress+Hauser AG
Level range: 150 mm - 1,200 mm
Process temperature: 0 °C - 70 °C
Precise level measurement in tight installation space due to compact probe head • For high-precision measurements of thin to viscous adhesives as well as (synthetic) resins and oils • Flexible use with or without ...
CAPTRON
Level range: 40 mm - 1,200 mm
Process temperature: -40 °C - 55 °C
... quick and easy, as no calibration is required without contact with the medium. The level probe also requires little space and is therefore suitable for complex, narrow tank geometries ...
CAPTRON
Level range: 200 mm - 1,000 mm
Process temperature: 0 °C - 70 °C
... PT100 temperature sensor in sensor tip Different probe configurations are available •Separate M8-conector The temperature signal is can be tapped at a seperate connector
CAPTRON
Level range: 0 m - 100 m
Process pressure: 0 bar - 10 bar
Process temperature: -25 °C - 85 °C
... developed for level measurement in waste water, sludge or water courses. The mechanical robustness of the flush ceramic diaphragm facilitates an easy disassembly and cleaning of the probe in case of service. Compared ...
BD|SENSORS GmbH
Process pressure: 0.4 bar - 25 bar
Process temperature: -10 °C - 70 °C
The level probe LMK 307 is designed for continuous level measurement in water or waste water applications. Basic element is a flush mounted ceramic sensor. Suitable ...
BD|SENSORS GmbH
Level range: 4 m - 250 m
Process pressure: 0.4 bar - 25 bar
Process temperature: -10 °C - 70 °C
BD|SENSORS has developed the stainless steel submersible probe LMK 307T with flush mounted ceramic sensor for continuous level and temperature measurement in water or waste water applications. The ...
BD|SENSORS GmbH
Process pressure: 10 bar
Process temperature: -25 °C - 80 °C
For pressurised tanks with no outside access The D45 Smart Level Transmitter is a probe most suited for measuring the level in pressurised tanks. It is compact yet ...
Level range: 30 mm - 8,000 mm
... and plug connector. The sensors are available in five detection ranges and cover a measuring range of 30 mm up to 8 m. Two output levels are available for all five detection ranges: - 1 pnp switching ...
microsonic
Level range: 250 mm - 1,300 mm
Process temperature: -25 °C - 70 °C
... ultrasonic transformer from the sensor housing. The M22 sensors detect in a contactless fashion and are reliable within a measuring range of 20 mm to 1,300 mm. The ultrasonic sensor ...
microsonic
Level range: 30 mm - 8,000 mm
Process pressure: 6 bar
Process temperature: -25 °C - 70 °C
... operating voltage LinkControl for configuration of sensors from a PC Description For fill level measurements of aggressive media and in overpressure the ultrasonic transducers of the new hps+ sensors ...
microsonic
... ADVANTAGES: - Constant and continuous indication of the level with high accuracy of repeatability. - Linear index of the level, regardless of the shape of the tank and the distance ...
... : - Constant and continuous indication of the level with high accuracy of repeatability. - Linear indication of the level, regardless of the shape of the tank and the distance between ...
Process temperature: -20 °C - 60 °C
Continuous level indicator certificate N° Tuv 12 Atex 109610 Electromagnetic Level indicators with a continuous signal 4-20mA Accuracy 12 mm USE: The level indicators ...
Level range: 6'00", 24'00", 12'00", 32'00"
Process pressure: 200 psi
Process temperature: -40 °C - 65 °C
... Series kits combine a continuous liquid level sensor paired with a pre-programmed panel meter display. Each kit offers a turn-key solution for critical tank measurement and process control. ...
Madison Company
Process temperature: -25 °C - 60 °C
The Laser level is an optical distance sensor adapted for measuring the quantity of lubricant present in pump reservoirs. This sensor can have a digital output that can be set to ...
Level range: 15, 7 m
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 80 °C
... plants Industrial processing of chemicals or fluids Day tanks, cooling towers, or waste sumps Plasticizer or resin tanks or silos Oil and fuel storage tanks Flood, ...
BinMaster
Level range: 49'00"
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 80 °C
... plants Industrial processing of chemicals or fluids Day tanks, cooling towers, or waste sumps Plasticizer or resin tanks or silos Oil and fuel storage tanks Flood, ...
BinMaster
Level range: 180'00"
Process temperature: 260 °C
The SmartBob2 series model SBR II manufactured by BIN MASTER® is a remote which utilizes a cable-based sensor technology. Integration with the Windows- based eBob software program as well as remote push-button controllers ...
BinMaster
Level range: 30 m
Process temperature: -40 °C - 80 °C
... electromechanical inventory level measuring system which uses state-of-the-art third generation weight & cable technology to periodically measure the level of liquid and bulk solid materials held in storage. ...
Level range: 0.07 m - 40 m
Process pressure: 5 bar
Process temperature: -30 °C - 95 °C
... ultrasonic sensors with integrated temperature compensation for connection to NivuMaster- Series evaluation units provide a wide variety of measuring options for liquids. The sensors provide accurate ...
Level range: 0.13 m - 15 m
Process pressure: 5 bar
Process temperature: -40 °C - 80 °C
Ultrasonic sensors with integrated transmitter for measurement of distance, level, empty space or volumes. Suitable for harsh ambient conditions. -Sensor as independent, comfortable ...
Process temperature: -30 °C - 85 °C
... connecting with the level data connector, obtain a complete measurement system. Typical level data collector applications Groundwater level measurement Landfill level ...
Level range: 1 m - 250 m
Process pressure: 0.1 bar - 25 bar
Process temperature: -10 °C - 70 °C
The stainless steel probe CPA-P-307 is designed for continuous level measurement in water and clean or waste fluids. Basic element is a high quality stainless steel sensor with high requirements for ...
SIMEX Sp. z o.o.
Level range: 1 m - 100 m
Process pressure: 0.1 bar - 10 bar
Process temperature: -20 °C - 80 °C
The separable plastic probe CPA-P-808 is designed for level measurement of water, waste water as well as fuels and oils. Basic element is a piezoresistive stainless steel sensor. In order to facilitate ...
SIMEX Sp. z o.o.
Level range: 1 m - 250 m
Process pressure: 0.1 bar - 25 bar
Process temperature: -10 °C - 70 °C
... -305 with silicon stainless steel sensor is designed for continous level measurement in confined space conditions. Permissible media are clean or waste water and thin fluids. A piezoresistive stainless ...
SIMEX Sp. z o.o.
Level range: 0 m - 250 m
Process pressure: 0 bar - 25 bar
Process temperature: -5 °C - 80 °C
Accuracy: ≤ ± 2.0 % FS Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA Materials: PVDF Customer benefits Chemical resistant level transmitter made of PVDF This transmitter has an excellent resistance to aggressive ...
Level range: 0.1 m - 25 m
Process pressure: 0 bar - 20 bar
Process temperature: 1,000 °C
POINT LEVEL MONITORING Microwawe barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fill level and limit detection FEATURES & BENEFITS - Simple and uncomplicated ...
Level range: 0.5 m - 500 m
Process temperature: -20 °C - 75 °C
This hydrostatic level probe allows liquids measurement and monitoring in tanks, rivers and groundwater. The level measurement is carried out by measuring the differential ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining