A critical issue with biomass and coal gasification processes is the presence of tar and dust in the process gas. These are usually removed by the client but it can occur that some remaining quantities need to be eliminated at the level ...
Cubic Sensor and Instrument Co.,Ltd
... monitoring Features : 1.Adopting UV DOAS technology, higher precision and longer life time. 2.Able to measure the lowest range of SO2 and NO in 100mg/m³. 3.Diagnostic function can check sensor status ...
Cubic Sensor and Instrument Co.,Ltd
... automatic sampling pretreatment unit and control unit, Gasboard-9081 is suitable to simultaneously measure NO, SO2,O2, O2, CO and CO2 concentration in flue gas. It is an on-line monitoring device dedicated to boiler emission ...
Cubic Sensor and Instrument Co.,Ltd
Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ mesurements with high accuracy, fast response, strong reliability and virtually maintenance free. FPI ...
Focused Photonics Inc.
... maintenance. With decades of experience in CEMS research and development, FPI launched diverse and state-of-the-art analyzers which analyzers can be integrated into a complete continuous émission monitoring ...
Focused Photonics Inc.
Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free. FPI ...
Focused Photonics Inc.
... utilizes ultraviolet (UV) spectroscopy to accurately monitor hydrogen sulfide (H2S) and sulfur dioxide (SO2) concentrations in sulfur recovery tail gas. The analyzer ...
AMETEK Process Instruments
... hydrogen sulfide (H2S) and sulfur dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It combines pulsed fluorescence detection with an internal catalytic ...
... absorption spectroscopy (UV-DOAS) technology. Compared with the Luft NDIR and Micro-flow NDIR flue gas analyzer, it can measure ultra-low range (0-50mg/m3) of SO2 and NO, which is widely ...
Cubic Instruments (Wuhan) Ltd.
... for emission measurement from various stationary sources. Furthermore, it can combine NDUV technology together to measure NO2 directly, which enables Gasboard-3000Plus to realize optical measurement of NO+NO2 at same ...
Cubic Instruments (Wuhan) Ltd.
Introduction Gasboard-3800Plus is new portable type to measure concentration of SO2, NO, CO, CO2 and O2 from stack or boiler emission gases, in which SO2, NO, CO are measured by unique dual beam micro-flow infrared sensors ...
Cubic Instruments (Wuhan) Ltd.
... high sulfur content, during combustion, will generate sulfur dioxide that further bebomes sulfite or sulfuric acid via chemical reaction to corrode engines. A large amount of sulfur ...
... photochemistry and modern sensing technologies, it can monitor concentration of trace SO2 in the ambient air continuously. Application Fields: Measurement of SO2 ...
... specifications Measuring Ranges NOx as NO2 (after NOx converter) - 0 – 100* / 1,500* / 5,000 mg/m3 SO2 - 0 – 75* / 1,500* / 7,500 mg/m3 CO - 0 – 75* / 3,000* / 12,500 mg/m3 O2 ...
ENVEA
... non-dispersive infrared method (NDIR-GFC) with gas filter correlation. O2 is measured by a built-in SRM paramagnetic sensor. The analyzer has been designed to meet the specific needs of on-site regulatory measurement ...
ENVEA
One single analyzer for the measurement of up to 50 parameters, to be selected according to the application. MCERTs certified Based on the FTIR technology (Fourier Transform Infrared) for simultaneous measurement of: ...
ENVEA
nfrared gas analyzers The range of Fuji Electric multi-gas extractive analyzers consists of non-dispersive infrared gas analyzers. A maximum of 5 gas components can be measured simultaneously ...
Portable NDIR analyzer & sample conditioning system - ZSVS / ZSVF Only available for countries outside of EU (no CE mark)! Compact NDIR gas analyzer system ZSVF: The compact type gas analyzer ...
... Interface) The ILA1-B000-EX In-situ Laser Analyzer measures sulfur dioxide (SO2) in real time and is designed for industrial applications as well as for use in potentially explosive ...
Overview: AQMS-500 SO2 analyzer adopts ultraviolet fluorescence method and combines with advanced microprocessor technology. It provides accurate and reliable detection of SO2 ...
... Online flue gas analyzer Product description Summary: ZWIN-CEMS06 flue gas analyzer is a gas analyzer independently developed by our company for environmental monitoring and on-line ...
For stable and efficient online measurement in all kinds of processes Chemical industry Recycling Environment Monitoring Control Pharmaceuticals industry …and other fields Housing: 400 mm deep, IP 20 Sample gas inlets: 1-inlet standard ...
... (NO) • NITROGEN DIOXIDE (NO2) • HYDROGEN SULPHIDE (H2S) • MERCAPTANS (R-SH) • CARBONYL SULPHIDE (COS) • CARBON DISULPHIDE (CS2) • SULPHUR DIOXIDE (SO2) • SULPHUR TRIOXIDE (SO3) • CHLORINE (Cl2) • CHLORINE ...
... elemental analyzer ELEMENTRAC CS-i measures the carbon and sulfur concentration in predominantly inorganic samples through combustion in an induction furnace and the subsequent analysis of the gaseous ...
APPLICATION Power plant / Waste incineration / Cement Petrochemical / Oil and Gas / Metal / Steel Paper / Pulp / Glass / Ceramics / Maritime / Boiler MEASURED COMPONENT NOx, SO2, O2 DSM-XG FEATURES 1. Ensures high precision ...
... method,eliminating the need for calibration 3. Selectively measures two gases out of NOx, SO2 and NH3 simultaneously 4. Enables individual NO and NO2 measurements without the ...
... (UV DOAS) 2. Enables individual NO and NO₂ measurements without the need for a NOx converter 3. Utilizes cost-effective zirconia principle for O₂ measurements CERTIFICATES / APPROVALS 1. Type Approval (Korea) 2. ...
It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm. Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted ...
Beijing Zetron Technology Co., Ltd
Simultaneously display the gas concentrations , repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. Graphical display, and use the form of the curve to reflect the trend of gas ...
Beijing Zetron Technology Co., Ltd
The MIC-600 laser analyzer adopts the principle of Tunable Diode Laser Absorption Spectroscopy (TDLAS), which is the \"single-line spectrum\" measurement technology. Using a high-stability, low-noise quantum cascade QCL ...
Beijing Zetron Technology Co., Ltd
Analyzers and Customer Solutions Analyzers for emission measurement and process control on NDIR and PAS basis The gas analyzers of smartGAS are high performance solutions for ...
High end flue gas emission analyser for H2-analysis at industrial sites Precise and very stable offset measuring technique by means of non dispersive infrared (NDIR) technique, for enhanced long time measurements ...
... of industrial applications. Gases Sensed - Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen Chloride (HCl), Methane (CH4), Nitric Oxide (NO), Nitrous Oxide (N20), Oxygen (O2), Sulphur Dioxide ...
Measured compounds SO2 – Sulfur dioxide –infrared analyzer Mod. Enox II Sampling and treatment system n. 1 Probe with heated filter, n. 1 Heated line, ...
... Infrared analyzer for the analysis of CH4, CO2 and CO Electrochemical analyzer for the analysis of O2 (oxygen) and H2S (sulfur dioxide / hydrogen sulfide) Flowmeters ...
The ULTRAMAT 7 offers high selectivity and measuring precision in complex gas mixtures as well as low maintenance costs due to easy on-site cleaning of the analysis cuvettes. In addition, the ULTRAMAT 7 features an integrated interfering ...
Siemens Process Analytics
Overview The APSA-370 is a device for the continuous monitoring of atmospheric SO2 using UV fluorescence. The APSA-370 employs an proprietary, internal dry-method sampling device to achieve the highest ...
HORIBA Process & Environmental
... 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 ...
AQ7010 sulfur dioxide analyzer is a SO2 analyzer based on ultraviolet fluorescence technology, which can be used to detect the ppb~ppm ...
✓ Multiple smart, microprocessor-controlled modules with robust Controller Area Network (CAN) Bus communications ✓ Single, common cable set from the mainboard provides both power and data along the CAN Bus - ✓ One single, common ...
Teledyne API
EM-5P portable flue gas analyzer is developed on UV DOAS (Ultra Violet Differential Optical Absorption Spectroscopy) technology. It can be used to monitor SO2, NO, O2 and other gas in flue gas. The detection low limit ...
Hangzhou Zetian Technology CO., Ltd
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining