YTMX580 can accept inputs from up to 8 points of measurement such as thermocouples (8 types: K, E, J, etc.) or RTD signals (3 types: Pt100, etc.), converting the corresponding measurement input values to a wireless signal. ...
YOKOGAWA Europe
RTD, TC, mV signal transmitter, DIN/B or DIN rail head mounting -With 3 customizable linearizations (up to 96 segments) -Reversible output (e.g. 20 to 4 mA) -Programmable retransmission range -Isolated ...
Din rail Transmitter for Thermocouples -Thermocouple input, two-wire output -SMART, programmable -Burnout, scale ranges and units of measure (°C -°F) programmable ...
Kimo's temperature measuring modules consist of four thermocouple temperature inputs.
The JUMO dTRANS T06 Junior multifunction four-wire transmitter is the solution for a wide range of applications in plant engineering due to its galvanic isolation and customer-specific linearization. This entry-level ...
... and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well ...
Endress+Hauser AG
... 53 C The OPTITEMP TT 53 C is a universal, programmable, 2-wire head-mounted temperature transmitter. The galvanically isolated transmitter works with RTD elements, thermocouple ...
... 53 R The OPTITEMP TT 53 R is a universal, programmable, 2-wire rail-mounted temperature transmitter. The galvanically isolated transmitter works with RTD elements, thermocouple ...
... product categories : Hockey-puck transmitter, In-head temperature transmitter Technical data Transmitter mounting : Head-mounted Galvanic isolation : No Transmitter ...
The new temperature transmitter TTH200 supports both the HART 5 and HART 7 protocol and is the standard device of the proven TTx200 / TTx300 product family in two-wire technology. The TTH200 is provided ...
ABB Measurement & Analytics
... rail-mount HART temperature transmitter in a compact 17.5 mm housing. The transmitter provides increased device safety in compliance with NE89 and NE107 and hardware write protection. The ...
ABB Measurement & Analytics
The TTF200 HART temperature transmitter completes the TTx200 / TTx300 product family in proven two-wire technology. The field-mount temperature transmitter TTF200 is ...
ABB Measurement & Analytics
... the WIKAsoft-TT software offers a line recording functionality where the temperature profile for the thermocouple connected to the T16 can be displayed. The model T16 transmitter features ...
... sensor Thermocouple, mV sensor Potentiometer Signalling in accordance with NAMUR NE43, sensorbreak detection in accordance with NE89, EMC in accordance with NE21 Description These temperature ...
... 's or A-D conversion cards in PC's. The temperature transmitters convert the temperaturedependent change in resistance of resistance thermometers or the temperature-dependent voltage ...
The SERIES 5750 temperature transmitter yields remarkably accurate temperature measurements and improves reliability, which reduces downtime and costs. It offers new measurements with ...
Enclosure Housing: Aluminum or SS316 Input: Programmable for thermocouple type K, J, R, Sf T, N, E, B and RTD PT100Q from a PC Working Span Range: Programmable from a PC LCD Display: 5 digital (-9999-69999) Sensor ...
Microprocessor based Housing: ABS plastic. Dimensions: 44 mm(diameter)x24.5 mm(height), installée) in thermocouple head Input: MV, ptlOOQ, thermocouple available Isolation: 4K Vac for 1 minute between ...
... configuration the transmitter can work alone without connecting to a power source. Technical Data Microprocessor Based DIN Rail Mount Configurable without external Loop Power Connected High accuracy in total ambient ...
transmitter, display, meter and controller in one package integrated radial temperature or temperature and humidity probe, Ø18 mm, L=40 mm, stainless steel 316L, PTFE filter ...
temperature and voltage transmitter RTD, thermocouple or milivotage input peaks detection function free selection of characteristics free data reading and configuration ...
... 0~5V/ 0~10V/ 0~20V 。DCA Input: 0~20 mA/ 4~20 mA 。Thermocouple Input: K / J / T / E / R / S / B / N 。RTD/ Resistance Input: PT100/0~400W 。Analog Output: 4~20 mA (Loop Power) 。Ambient temperature: ...
Powerful high-accuracy loop-powered head mounted temperature transmitter, it accepts several types of temperature sensors – thermocouples, Pt100, Pt1000, NTC and 0-50 ...
... 25 °C): typical 0,1% of span for thermocouple, mV, Pt100 and Pt1000 - Temperature effect <± 0,16% @ 25º C - Configurable output to 4-20 mA loop powered or 0-10 V - Output Linearized according with ...
TxIsoRail is fully programmable isolated temperature transmitters dedicted to Pt100 and thermocouple industrial sensors. TxIsoRail is a DIN rail mount unit. Both units can be easily user ...
Pt100 or Thermocouple integral sensor The DPT-2000 Temperature Transmitter is suitable for measuring temperatures between -200°C and 550°C, and comes with custom probe ...
The KT-502H series temperature transmitters with HART protocol supports 22 types of input. The display can be rotated 330° and the backlit display offers high visibility even in dark environments. Main ...
... 502H series temperature transmitters with HART protocol supports various input options for use with diverse temperature sensors. The series offers high accuracy temperature ...
... The NPT3 is designed for universal use in industrial applications. These temperature transmitters can be applied to all automation systems in which different types of temperature sensors ...
... universal temperature transmitter in a 6-mm wide slimline DIN rail mounting enclosure. The device is intended for the conversion of the measurement signal from a TC or a 2-, 3-, or 4-wire RTD into a 4-20 ...
The NPT1 is a universal temperature transmitter for DIN rail mounting. The device converts the sensor signal from a thermocouple or RTD to a 0(4)-20 mA standard signal. The configuration ...
• linear processing of the measured temperature into a current or voltage signal • output: - voltage 0÷10V (3-wire) • no galvanic separation input / output • housing for mounting on TS35 strip (DIN rail) • input ...
APLISENS S.A.
• linear processing of the measured temperature into a current signal • input (programmable): • input type, processing range and other processing parameters configured with AR950, AR956 programmer or AR956 programming ...
APLISENS S.A.
The rail-mounted smart temperature transmitter type LI-24 and LI-24Ex has an output of 4 to 20mA + HART, an in-out galvanic insulation and is ATEX certified. It features an automatic diagnostic system, ...
APLISENS S.A.
TS 2 Wire Temperature sensor & Transmitter ● Accuracy: RTD: 0.5%, T/C: 0.75% ● Wide selection of input ● Low output ripple ● High stability & low cost
TT Temperature Signal Transmitter (Head Mounting) FEATURES: ● Output: 4~20mA (2 wire) ● Accuracy: T/C: 0.3% Pt100Ω: 0.15% ● Wide selection of input with difference sensor type & range ● Dimension ...
COMECO’s current loop transmitter TRN converts the signal from a temperature sensor into standard current or voltage signal that can be safely sent over long distances to remote indicators, data loggers, ...
Comeco Control & Measurement
Field mounted HART temperature transmitter • RTD, TC, Ohm, and bipolar mV input and analog output • High definition local operator interface (LOI) with 3 optical buttons • Selectable red or white ...
PR ELECTRONICS
The temperature transmitter MSTS-WT is equipped with a thermocouple input type K, as well as RTD (Pt100) and one 4-20 mA analog output (2-wire). The configuration happens via HART interface/software. ...
Head mounting transmitter. Programming via PC interface. 4-20 mA output 2 wires (optional HART protocol). Input resistance thermometers (PT100, PT1000, Ni100, etc.) or thermocouples (J, K, T, R, S, T). ...
... BA474D loop powered indicating temperature transmitter provides a large, easy to read, digital temperature display plus accurate 4/20mA analogue and HART® digital outputs. Optional alarm ...
BEKA
Configurable 2-wire 4-20 mA temperature transmitters for probe head or DIN guide mounting, ready to connect to standard Thermocouple and RTD. The input and range can be configured by ...
The TR310 is a HART 5,6,or 7 compatible universal transmitter. It accepts RTD, Thermocouple, Potentiometer or millivolt input signals and converts them to the industry standard (4 to 20) mA transmission ...
British Rototherm Co. Ltd
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining