- Electricity - Electronics >
- Electronic Component >
- Three-phase electronic filter
Three-phase electronic filters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 1 A
... range: -40℃ to +105℃ - Compact size RoHS FL4D-Z8-302-XJ ---- one of Mornsun’s common mode inductance, which is designd for three-phase power products. After adding a FL4D-Z8-302-XJ at the input of the ...
Frequency: 44 Hz - 66 Hz
Voltage: 520 V
Primary current: 16 A
Filters of the NFK855-31 series are used to suppress circuit-bound interferences in three-phase AC power lines without neutral conductor. Interference pulses or interference voltages ...
FEAS GmbH
Frequency: 44 Hz - 66 Hz
Voltage: 520 V
Primary current: 20 A
Filters of the NFK855-31 series are used to suppress circuit-bound interferences in three-phase AC power lines without neutral conductor. Interference pulses or interference voltages ...
FEAS GmbH
Frequency: 40 Hz - 66 Hz
Voltage: 520 V
Primary current: 25 A
Filters of the NFK5135-25A31 series are used to suppress circuit-bound interferences in three-phase AC power lines without neutral conductor. Interference pulses or interference voltages ...
FEAS GmbH
Frequency: 60, 50 Hz
Voltage: 480, 400 V
Primary current: 30 A - 400 A
... filtered for maximum filter effectiveness Power factor correction both inductive and capacitive Phase current balancing, improvement of consumption in neutral (4W model) If higher filtering ...
Suppressor modules from Murrelektronik ensure machine availability. The benefits of suppressor technology are enormous and far outweigh the measures linked with its deployment. For a small price, you can prevent malfunctions or faults ...
MURRELEKTRONIK
Frequency: 0.06 kHz
Voltage: 300, 277 V
Primary current: 7 A - 180 A
... attenuation performance from 150 kHz to 30 MHz Excellent saturation resistance up to 50 m cable length Most compact and slim filter design in its class Operating frequency : DC to 60 Hz Rated current : 7 to 180 A Attenuation ...
Schaffner EMV AG
Frequency: 60 Hz
Voltage: 690 V
Primary current: 10 A - 160 A
Standard and high performance EMC solution Footprint space-saving book-style housing Solid safety connector blocks Standard attenuation performance FN 3287 High attenuation performance FN 3288 HV versions for 690 VAC applications HVIT- ...
Schaffner EMV AG
Frequency: 0 Hz - 60 Hz
Voltage: 480, 520, 300 V
Primary current: 8 A - 160 A
Compact, space-saving design, optimized for industrial machinery Combines high attenuation performance with low leakage current Performance according to the machine tool standard EN 50370-1 Increases also the immunity if operated directly ...
Schaffner EMV AG
... interference and harmonics. The portfolio includes double chokes for single-phase lines as well as triple and quad chokes for three-phase connection, with or without ...
Frequency: 50 Hz
Voltage: 380 V
Primary current: 188 A
... harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to ...
Shenzhen Sikes Electric Co., Ltd.
Frequency: 50 Hz
Voltage: 400 V
Primary current: 10 A
Optimize harmonic performance Advanced Harmonic Filter PHF 005/010 is a cost-effective total solution. Compared to traditional harmonic trap filters PHF offers a smaller foot print and higher harmonic ...
Shenzhen Sikes Electric Co., Ltd.
Frequency: 50 Hz
Voltage: 400 V
Primary current: 22 A
Optimize harmonic performance Advanced Harmonic Filter PHF 005/010 is a cost-effective total solution. Compared to traditional harmonic trap filters PHF offers a smaller foot print and higher harmonic ...
Shenzhen Sikes Electric Co., Ltd.
Frequency: 50 Hz
Voltage: 300 V - 720 V
Primary current: 6 A - 400 A
Design : Universal horizontal high-performance two-stage filter. Typical Applications Variable speed electric drive systems/motor drives primarily for industrial use. Various industrial applications, ...
SHENZHEN DAQI INDUSTRIAL DEVICE CO.,LTD.
Frequency: 50 Hz
Voltage: 380 V - 520 V
Primary current: 5 A - 200 A
... comprehensive range of filters. Available for single and three phase power supplies. EBA Series Typical Applications Three-phase variable speed motor ...
SHENZHEN DAQI INDUSTRIAL DEVICE CO.,LTD.
Frequency: 50 Hz
Voltage: 300 V - 720 V
Primary current: 1 A - 40 A
Three-phase variable speed drive and power drive system (PDS). Applied to energy conversion device (inverter, converter). Three-phase power supply. Advantages Designed ...
SHENZHEN DAQI INDUSTRIAL DEVICE CO.,LTD.
Frequency: 0 Hz - 100 Hz
Voltage: 208 V - 690 V
Primary current: 4 A - 300 A
Carrier Frequency - 0 – 16 kHz Dielectric test phase – phase - 2400 Vdc (2 sec.) Dielectric test phase – ground - 3200 Vdc (2 sec.) Protection Degree - IP00 integrable in cabinet IP21, ...
IREM SPA
Frequency: 60, 50 Hz
Voltage: 300, 520 V
Primary current: 3 A - 20 A
• Line filter as standard, industrial and medical version • 1 stage • Filter with standard or high attenuation (HP) Unique Selling Proposition • Compact single-stage filter • Various ...
SCHURTER
Frequency: 50 Hz - 60 Hz
Voltage: 480 V
Primary current: 3 A - 16 A
... mA Ambient temperature max. 45 °C Degree of protection IP 20 Advantages For general requirements Single‑stage filter concept Efficient filter effect against line‑bound interference emissions Increase ...
Block Transformatoren-Elektronik
Frequency: 60, 50 Hz
Voltage: 380 V
Primary current: 15 A - 300 A
Active power filter (APF:Active power filter) with parallel connected to the grid, through real-time detecting the load harmonic and reactive component and the PWM converter technology, and harmonic and ...
Frequency: 50, 60 Hz
Voltage: 208 V - 690 V
Primary current: 50 A - 450 A
... which make this device highly controllable and reactive. • The unique phase-splitting harmonic extraction algorithm is adapted. When the three-phase load is imbalanced, each phase ...
Frequency: 50, 60 Hz
Voltage: 380 V - 690 V
Primary current: 10 A - 480 A
... must be implemented in the cabinet as part of the installation) VLT® Advanced Harmonic Filter AHF 005 and AHF 010 are robust and easy-to-use passive harmonic filters that reduce harmonics while maintaining ...
Danfoss VLT Drives
Frequency: 63 Hz
Voltage: 520 V
Primary current: 16 A - 125 A
Line Filter with PreLEAK® TECHNOLOGY for a safe operation on the RCD No faulty RCD trippings while switching machines and systems on or off No leakage current spikes while connecting and disconnecting the CEE plug Very ...
EPA GmbH
... interference pulses are effectively attenuated by the EMC filters regardless of location. The EN55011 standard (limit values and measurement methods) regulates the use of EMC filters. The mains filter ...
Frequency: 150 kHz - 1,000 kHz
Voltage: 500 V
Primary current: 6, 10, 20, 30 A
Good attenuation characteristics (150kHz÷1MHz). Quick and easy push-down terminal block. Safety cover.
DETAS
Frequency: 200 kHz
Voltage: 85 V - 528 V
Primary current: 3, 6 A
SynQor provides 3-phase AC-DC EMI filters for the Mil-COTS series converters. All EMI filters provide differential mode attenuation and common mode attenuation (model dependent) and include ...
SYNQOR
The FA type filters, are designed to reduce the presence of non- sinusoidal currents, generated by U.P.S., in industrial networks. The TUNED FILTER type FA is a PASSIVE system, designed by correctly ...
COMAR CONDENSATORI
3-Phase Filters LF-10520 rated current 10 A @ 50°C LF-20520 rated current 20 A @ 50°C LF-30520 rated current 30 A @ 50°C LF-50520 rated current 50 A @ 50°C
Frequency: 50 Hz - 60 Hz
Voltage: 600 V
Primary current: 3 mA
Very high differential and common mode attenuation Very low leakage current (<3mA) Benefits 5 Year warranty Safety terminal block connector Helps pass the immunity test for the IEC61000-6-2 Standard Markets ...
ENERDOOR
Frequency: 14 MHz - 55 MHz
Code SS5 Electrical specifications • Rated voltage : 440 VAC • Power line frequency : 50/60 Hz • Max. leakage current for standard version each line to ground @ 10 A 250VAC 50Hz: 1,0mA @ 20 A 250VAC 50Hz: 4,0mA • Hi-pot rating ...
COMESTERO SISTEMI
Frequency: 50, 60 Hz
Voltage: 480 V
Primary current: 5 A - 1,600 A
... the inverters output filter. An EMI filter, or electromagnetic interference filter, is an electronic passive device which is used in order to suppress conducted interference ...
MTE Matrix Filters solve the problem of harmonic distortion on virtually any kind of six pulse rectifier. These power supplies are commonly found in three phase electronic ...
MTE
LCL filters, which are particularly popular in the renewable energy industry today, are an efficient and economical way of ensuring and improving the quality of power fed from the energy source to the grid. Their purpose ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining