- Electricity - Electronics >
- Energy: Production and Distribution >
- Three-phase transformer
Three-phase transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output power kVA: 0, 0.01 kVA
Primary current: 100 A - 3,000 A
Secondary current: 5 A
... Degree) - Tropicalization - Impossibility of tampering with the transformer, preventing any form of access to the internal elements. Applications Current transformers for energy meters. Used ...
Primary current: 63 A - 250 A
Secondary current: 250 mA
Frequency: 50, 60 Hz
Current transformers specially designed to be installed above a switch Transformer range from 63 to 250 A Secondary 250 mA Compatible with the MC product range from CIRCUTOR. Applications Installation ...
Electric power: 10 W - 100 W
Primary voltage: 400, 230 V
TSA is a third harmonic filter based on a insulation transformer with a star- triangle connection (D-Y), which eliminates third order harmonics and has a passive 5th order harmonic filter in the secondary panel. Therefore, ...
The current sense transformers from Standex Meder Electronics are designed for extreme temperature, humidity, radiation and other harmful environments. The 3-phase current transformers ...
Primary voltage: 0 V - 300 V
Secondary voltage: 0 V - 600 V
Frequency: 50, 60 Hz
Three-phase voltage transformer VBO3 is a three-phase voltage transformer with a transformation ratio of 1:2 and extends the range ...
Primary current: 40 A - 250 A
Secondary current: 5 A
Frequency: 40 Hz - 60 Hz
Measurement current transformers for currents from TAM series Modular LV analog current transformers, 2 modules width, from DIN bar for currents
Output power kVA: 0 kVA - 0.2 kVA
Primary current: 40 A - 4,000 A
Secondary current: 1 A - 5 A
"THROUGH BAR" measuring current transformers for currents
Output power kVA: 0.01 kVA - 0.01 kVA
Secondary voltage: 100 V - 100 V
Frequency: 40 Hz - 60 Hz
Measurement voltage transformers for voltages from
Output power kVA: 1 kVA - 800 kVA
Frequency: 50 Hz - 400 Hz
- Thermal class: B, F or H depending on power - Separate windings - Electrostatic screen to ground, between primary and secondary - Operating temperature: 40 ° C standard or according to specifications - With or without case (IP23, ...
Output power kVA: 50 kVA - 2,500 kVA
Scope of application: SC series dry-type transformers can be used as replacement products for oil-immersed transformers. Especially suitable for high-rise buildings, commercial centers, hospitals, laboratories, ...
Ningbo Tianan (Group) CO.,Ltd.
Output power kVA: 30 kVA - 2,500 kVA
Primary voltage: 10, 20, 35 kV
S13-M series three-phase oil-immersed fully-sealed distribution transformers are different from ordinary oil-immersed transformers. It eliminates the oil conservator. ...
Ningbo Tianan (Group) CO.,Ltd.
Output power kVA: 7.4 kW - 626.7 kW
... advanced level. Among them, the three-phase three-coil on-load tap-changing transformer passed the type test at one time in 2003 and is the first domestic manufacturer ...
Ningbo Tianan (Group) CO.,Ltd.
Output power kVA: 4 kVA
Primary voltage: 440 V
Secondary voltage: 380 V
Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 12.5 kVA
Primary voltage: 380 V
Secondary voltage: 380 V
Photovoltaic isolation transformer encapsulated 12.5Kva for solar power or wind power transmission Description of Power Isolation transformer: SGGF isolation transformer is used to ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 100 kVA
Primary voltage: 380 V
Secondary voltage: 385, 222 V
Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Primary voltage: 220 V
Secondary voltage: 220, 380, 440 V
The PTU-03 Isolation Transformer Module is an optional add on accessory for the ECU-02 or AVR. Compatible with single and three phase voltage and isolates the primary and secondary voltage. ...
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
Dry type transformer. All transformers are tropicalized with anti-flash varnish: • Protection against corrosive environments. • Greater electrical insulation. • High compaction power. • Noise level reduction. • ...
POLYLUX S.L.
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
... ISO 12994-2).) Tailor made, if the standard specifications are not what is required. • TTF transformers are used for galvanic isolation of three-phase solar installations. • They ...
POLYLUX S.L.
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
TT transformers are used for insulation galvanic three-phase installations for reasons of security. They are also used in the generation of neutrals referenced to ground in single-phase ...
POLYLUX S.L.
Electric power: 252 W - 5,500 W
Output power kVA: 100 kVA - 3,150 kVA
This kind of transformer complies with EU Ecodesign Direc- tive (EU548/2014) and with the IEC 60076-11:2018-10 standard. It makes it possible to reduce energy consumption and, as a consequence, to reduce greenhouse emissions. ...
Tesar Srl
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
... and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to 2000 kVA Frequency: up to ...
Output power kVA: 0.01 kVA
Primary current: 5 A
- Ratio x/5A - Accuracy class 0.5 and 0.2S Screw mounting
Secondary voltage: 333 mV
Primary current: 30 A - 600 A
Frequency: 50, 60 Hz
The QI-KCT version is a split core current transformer with secondary at 333 mV, which can be used with our QE-POWER-T three-phase power meter as a smaller and cheaper option. The ...
Electric power: 0.5 kVA - 160 kVA
Three-phase Transformers designed and manufactured to comply with IEC61558 and IEC60076. These are double-wound Isolation Transformers for continuous duty and complete ...
Electric power: 160 kVA - 750 kVA
Three Phase Transformers 160 - 750kVA Three-phase Transformers designed and manufactured to comply with IEC61558 and IEC60076. These ...
Output power kVA: 0.15 kVA - 100 kVA
Primary voltage: 200 V - 600 V
Secondary voltage: 42 V - 600 V
... EN 60558 Three-phase Transformers are general purpose transformers made to be used in all three-phase systems. They can be used in ...
Secondary voltage: 0 kV - 765 kV
The transformative role of phase shifters in the energy transition Phase shifting transformers are key to creating balance within and between power networks. With their capability ...
Siemens Energy – Power transmission
Output power kVA: 45 kVA - 5,000 kVA
Primary voltage: 200 kV
Prolec GE offers a complete line of liquid-filled three-phase pad-mounted distribution transformers that meet applicable IEEE standards. These transformers are specifically ...
GE Grid Solutions
Output power kVA: 7,000 kVA
Primary voltage: 36, 72.5 kV
Frequency: 50, 60 Hz
... turbines, Hitachi Energy has developed a transformer that is able to step up the voltage at a world record of 66 kV and meet the most stringent electrical and mechanical requirements. With its WindSTAR™ transformer, ...
Output power kVA: 20,000 kVA - 40,000 kVA
Primary voltage: 15 V - 20 V
Secondary voltage: 15 kV - 20 kV
Frequency injection transformer in mineral oil, installed in the HVB/HVA source station outside: enables the injection of remote control signals. Main characteristics • Oil filled transformer ...
Cahors
Primary voltage: 765 kV
... form large power transformers typically use more electrical steel for the core and are more resilient to short-circuit in the transmission systems and are frequently used in industrial applications With shell-formed ...
Output power kVA: 16.3 kVA
Primary voltage: 415 V
Secondary voltage: 0 V - 470 V
... This model is part of RS PRO's series of professional 'Varivolt' transformers that come in a variety of current ratings and in both single and three-phase versions. These transformers ...
Electric power: 1,000 W - 30,000 W
Primary voltage: 400 V
Secondary voltage: 400 V
General Data Rated input voltage 3 x 400 Vac Rated output voltage 3 x 380 ‑ 3 x 420 Vac Rated power 1000 ‑ 30000 VA Insulation class F Maximum ambient temperature 50 °C Efficiency up to 97.5 % Degree of protection IP 00 or IP 23 Optionally ...
Primary voltage: 400 V
Secondary voltage: 230 V
Primary current: 3 A - 15.6 A
The transformers of the DS0107 series have reinforced insulation and comply with the requirements of IEC 61558-1 / DIN EN 61558-1 (VDE 0570-1) and IEC 61558-2-15 DIN EN 61558-2-15 (VDE 0570-2-15). In addition, the ...
Primary voltage: 10, 20, 35 kV
Overview SC (B) 10/11 epoxy cast dry-type transformer is a dry-type transformer with strong mechanical strength, electrical strength, and good heat-resistance performance. It is made of F class epoxy ...
Beijing SOJO Electric Co., Ltd
Electric power: 10,000 kVA - 25,000 kVA
Primary voltage: 12 kV - 145 kV
The CG Small Power Transformers are mainly used for the distributing of networks. These devices feature customized structures, with cost-effective concept. They are characterized by minimal loss, and low noise, enabling ...
CG Power Systems
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining