- Electricity - Electronics >
- Switch and Relay >
- Time delay monitoring relay
Time delay monitoring relays
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... module models have a variety of safety inputs, solid-state safety outputs and safety relay outputs • Innovative live display feature and diagnostics allow for active monitoring of I/O on a PC and assist ...
Tripping current: 200 mA
Trigger voltage: 24 V
Multifunctional safety relay module for superior diagnostics and visualisation Suitable for the signal processing of outputs with contact sensors Suitable for the signal processing of outputs with contact ...
Tripping current: 125 mA
Trigger voltage: 230, 24, 115 V
Multifunctional safety relay module for superior diagnostics and visualisation Suitable for the signal processing of outputs with contact sensors Suitable for signal processing of outputs connected to potentials ...
Tripping current: 6 A
Trigger voltage: 24 V
... V Voltage permitted at the input - 30 V Test pulse time permitted tTP - 1 ms Release time tR - ms Release time tR, time-delayed contacts (tolerance) - 0.1 s ... ...
The multifunctional safety module UG 6970 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. Up to two independent safety functions which are selected in a simple way ...
... multifunctional safety timer UG 6960 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. The UG 6960 combines safety time functions ...
... SLS (safely limited speed), SSM (safe speed monitoring), SSR (safe speed range) and SDI (safe direction) in accordance with EN 61800-5-2. Advantages and customer benefits - Direction of rotation monitoring ...
Tripping current: 20 mA
Trigger voltage: 24 V
... tampering is provided. • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary • Earth fault/ground fault ...
Tripping current: 0.03 A - 5 A
... Sensitivity and trip time Output contact status. Protection status messages. Real time level of leakage. LED bars that show the percentage leakage current measured by the unit. Two independent programmable ...
Tripping current: 10 A
... is an AC current monitoring in 1-phase which is equipped with thresholds and hysteresis. The multifunction device also has tripping delay that helps in monitoring relays. ...
TELE Haase Steuergeraete GmbH
Tripping current: 100, 1, 10 mA
Current monitoring single phase; Multifunction; to 10A; Fault latch; 2 CO, Adjustable delay
TELE Haase Steuergeraete GmbH
Tripping current: 2,000 mA
Current monitoring single phase; Multifunction to 2A; Fault latch; 2 CO, Adjustable delay; coolZoom
TELE Haase Steuergeraete GmbH
Tripping current: 4, 6 A
Trigger voltage: 240, 250, 24 V
... signal output, can be used for alarm. Provides rich fault diagnosis information through the change of indicator lights. The delay range is 0-99 seconds, with adjustable accuracy of 0.1 seconds between 0-10 seconds and ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 240, 250, 24 V
... signal output, can be used for alarm. Provides rich fault diagnosis information through the change of indicator lights. The delay range is 0-99 seconds, with adjustable accuracy of 0.1 seconds between 0-10 seconds and ...
Bytorent Technology Co., Ltd.
Tripping current: 6, 4 A
Trigger voltage: 250, 240, 24 V
... can be used for alarm. Provides rich fault diagnosis information through the change of indicator lights. Delay dialing setting, adjustable delay range of 0-7.5 seconds, in units of 0.5 seconds, with ...
Bytorent Technology Co., Ltd.
Trigger voltage: 24 V
... interlocking devices with guards, associated with machinery with inertia, where the dangerous situation can last for a defined time after stop signal generation 2 safety NO OSSD delayed outputs + 2 safety NO OSSD instantaneous ...
... flexibility. •Non-Delayed contact outputs •Off-delay contact outputs •Pick-up delayed contact outputs •Time delay adjustable on the unit Emergency Stop- & Time ...
Tripping current: 5, 10 A
Trigger voltage: 115, 230 V
Fluid Level Monitoring Relay 230VAC Sensitivity Adjust On Delay and Off Delay Timer Filling & Emptying Functions Key Features • Compact 36mm Design • ...
Trigger voltage: 415, 220, 380, 400 V
... failure relay monitors phase sequence, phase break and undervoltage. The output relay is energized when all three phase voltages are present and the phase conditions (voltage and phase sequence) are correct. ...
Tripping current: 8 A
Trigger voltage: 250 V
... stoppage without external sensor Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Time before dangerous failure: MTTFd = 100 years Cycle before dangerous failure: B10d=100,000 ...
Trigger voltage: 400, 230, 380, 415 V
○3-phase monitoring of phase-neutral voltages ○3-phase monitoring of phase-phase voltages ○Built-in adjustable time delay ○Individual adjustment for min and max limits ○1-pole ...
COMADAN
Trigger voltage: 24 V - 240 V
The Current monitoring relay PRI-51 features its ability by controlling the heating of rods in shunts, of cables, to direct current flowing, to monitor utilization of single-phase electrical loads. This ...
ETI
... status indicators fro the faulty conditions. An adjustable time delay and 2 C/O configuration is included in the product unit. • Protects against Phase Loss, Phase Reversal & Phase Asymmetry • Suitable ...
General Industrial Controls (P) Ltd.
Tripping current: 0.02 A - 2 A
- Under or Over current monitoring (selectable) - 3 Selectable current ranges (0.2A, 1A or 2A) - Adjustable Trip level, Hysteresis and Time delay + Latch - Isolated Auxiliary supply - ...
Broyce Control
... check for correct opening of external machine contactors. For applications requiring time controlled delay after opening of the guard switch, versions with time delayed output contacts ...
Idem Safety Switches
... positive guided safety contacts: 3 NO contacts, 1 NC contact for AC 250V •adjustable voltage setting •adjustable standstill time delay •LED indicators for standstill, event of line breakage and ...
Tripping current: 16 A
... single-state switching. You can choose between functions drain in, drain away or a combination of these two. Adjustable time delay (0,5-10s).TECHNICAL PARAMETERS Supply AC 230 V, AC/DC 24 V or ...
ELKO
... MS2V67-S Series relay is a three pole voltage monitoring relay with four stages of adjustable voltage pick up & drop out points. Each voltage set point can be set for under or overvoltage ...
Tripping current: 0.1 A - 25 A
... current monitoring relays are used for the control of AC and DC current signal in various industrial and domestic applications. The measuring part of the instrument is metallically separated from the ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining