Electric power: 0.03 kVA - 0.25 kVA
Primary current: 0.08 A - 1.35 A
Transformers have to be flexible because different situations require different voltages. Murrelektronik's product range offers this flexibility, no matter if it's an isolation transformer, control transformer, ...
MURRELEKTRONIK
Output power kVA: 0.105, 210 kVA
Primary voltage: 115, 230 V
Secondary voltage: 24 V
The Safety isolating transformer of the PST100 series are powerful and robust transformers to power devices with low alternating input voltage. The PST10024 transforms AC line voltage into short circuit ...
Output power kVA: 0.105 kVA
Primary voltage: 115 V - 230 V
Secondary voltage: 12, 24 V
The Safety isolating transformer of the PST100 series are powerful and robust transformers to power devices with low alternating input voltage. The PST10012 transforms AC line voltage into short circuit ...
Primary current: 5 A - 8,000 A
Frequency: 50 Hz - 60 Hz
self estinguishing thermoplastic material UL94-V0 operating frequency 50÷60 Hz insulation reference voltage 0,72 kV test voltage 3 kV x 1’ 50 Hz insulation classe E protection degree IP 20 continuous overcurrent 1,2 In rated ...
Output power kVA: 0.01, 0.02, 0.04 kVA
Frequency: 50 Hz - 60 Hz
operating frequency 50-60 Hz min. rated burden 2VA insulation reference voltage 0,72 k V test voltage 3 kV x 1'50 Hz insulation classe E protection degree IP 30
Output power kVA: 0 kVA - 0.2 kVA
Primary voltage: 100 V - 1,200 V
Secondary voltage: 100, 110 V
DESCRIPTION Measuring VT's cl.0.5 DETAILS QUICK DELIVERY Technical data self estinguishing thermoplastic material UL94-V0 operating frequency 50÷60 Hz insulation reference voltage 0,72 kV test voltage 3 kV x 1’ 50 Hz insulation ...
Primary current: 1 A - 300 A
Secondary current: 5, 1 A
Frequency: 40 Hz - 60 Hz
Winding primary current transformer Protection current transformer Fixing with DIN rail and wall mounting 6mmq terminals connection Small size High performance ...
Output power kVA: 0 kVA - 0.2 kVA
Primary current: 40 A - 4,000 A
Secondary current: 1 A - 5 A
"THROUGH BAR" measuring current transformers for currents
Output power kVA: 0.01 kVA - 0.01 kVA
Secondary voltage: 100 V - 100 V
Frequency: 40 Hz - 60 Hz
Measurement voltage transformers for voltages from
Electric power: 200 W - 400 W
Output power kVA: 0.2 kVA - 0.4 kVA
Primary voltage: 10 V - 24 V
General Characteristics • Dimensions according to CEI-UNEL 21009 std • Manufactured and tested acc. to IEC 61869-1/2 • Rated Insulation level up to 36 kV • Frequency 50 or 60 Hz • Rated primary current (Ipr) Single primary ...
Electric power: 200 W - 400 W
Output power kVA: 0.4, 0.2 kVA
Primary voltage: 10 kV - 24 kV
The peculiar characterisNcs of this innovaNve product consist in having a phase-to- phase VT to be connected to the MV line through plug-in bushings, type A interface, protected by two MV fuses, all contained in an ≥ IP 55 metal case; ...
Primary current: 100 A - 5,000 A
Small size and easy mounting. Range output burden: 100A - 5000A. High accuracy and reliability. TECHNICAL SPECIFICATION - Indoor use. - Policarbonate with self-extinguishing V0. - Sealable secondary terminals. - Highest voltage ...
Primary current: 1 A - 4,000 A
The TCB's different characteristics are fixing system: to wall, to cable/passing bar or to DIN rail by accessories supplied with the CT, Measuring Transformers: the short circuit on terminals ...
Primary current: 30 A - 2,000 A
... developed to fix systems. It can either be place into walls, DIN rail by an accessory provided with the C.T. or be place directly to cable by screws also provided with the C.T.. In measuring transformers, ...
Primary current: 1 A - 7,500 A
Frequency: 50, 60 Hz
... OPTIONS • - Plug-in metal feet for wall or base mounting • - Moulded busbar mounting • - Primary copper busbar mounting • - Multi busbar mounting ...
Crompton Instruments
Output power kVA: 3 kVA - 500 kVA
Secondary voltage: 600 V
IP20 Wall Mounted SY/EY/TY/FY Series Applications Machinery equipment IC Semiconductor SMT/PCB electronic assembly Internet communication system Military control system Data ...
Electric power: 0.01 kVA
Secondary voltage: 4, 8, 12 V
10VA transformer for continuous service, outputs 4-8-12V 2 DIN Power supply 230V a.c. – 50Hz Outputs 4-8-12V Installation on terminal board IP20 Wall-mounted IP30 Installation on the rear of the switchboard ...
Primary current: 250, 160, 630 A
Secondary current: 1 A
... 50mm • Burden : 1VA • Wall Mount Brief Specifications Features : Sensitive, Accurate Accuracy : Class 1.0 Current Transformer Type : Rectangular Window Type Input Current : 160A, 250A, 630A Mounting ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining