- Industrial machines and equipment >
- Heat Exchanger and Refrigeration >
- Water cooler
Water coolers
Power: 15, 7.5, 5.6, 27, 19 kW
The necessary ice water vats to include to the mix treatment plants Mod. Mixworking, supply ice water (+2°C) to both the ageing vats for the conservation of the mix at 4°C and to the plate exchanger for ...
Power: 2,000 W - 170,000 W
Maximum temperature: 5 °C - 45 °C
Power: 9.5 kW
... thus having smaller footprint & wiring Expand your range of applications - Water cooling options available, usable in secondary battery manufacturing Use it outdoors - Water splash-resistant, IPX4 compliant Cut ...
Power: 76 kW - 360 kW
Maximum temperature: 5 °C - 45 °C
... • Large water tanks allow minimum compressor cycling and precise temperature control. • Double independent fridge circuits. • 2 compressors from ICE076 and 4 compressors from ICE150 with automatic rotation. • ...
Power: 2 kW - 360 kW
Maximum temperature: 0 °C - 25 °C
... Carbon dioxide (CO2) lasers, excimer lasers, ion lasers, solid-state lasers, and dye lasers all use liquid cooling to remove excess heat. Laser liquid cooling can help accomplish three goals: • Maintaining ...
Power: 20 kW - 150 kW
... with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System ...
Power: 1.3 kW - 159.4 kW
Maximum temperature: 23 °F - 108 °F
Pressure: 65, 70, 75, 40 psi
... process chillers are at the heart of many operations. Many times, if the chiller goes down, the whole process shuts down. Therefore, the chiller shouldn't be seen as an afterthought, ...
Exact temperature control by water-cooling system Depending on the different applications, a polyurethane system often requires extremely exact temperature control methods. Hennecke uses industrial chillers ...
Power: 765 W - 2,750 W
Maximum temperature: -10 °C - 40 °C
Flow rate: 14.7, 11 l/min
... alternative to tap water cooling, these Recirculating Chillers reduce water consumption, while the patented WhisperCool® Environmental Control System reduces noise levels below conversational ...
Power: 5 kW - 180 kW
Maximum temperature: 7 °C - 35 °C
Flow rate: 3.6 m³/h - 33 m³/h
... computer, accurate temperature control. •Pump overload protection to ensure service life effectively. • Alarm device for low liquid level to guarantee system running safety. Switch of main power source conforms to CE ...
Power: 15 kW - 360 kW
Maximum temperature: 7 °C - 35 °C
Flow rate: 5.4 m³/h - 90 m³/h
CE Certificated Description Benefits & Features •The device can cool the water temperature ranging from 7 to 35oC. •The low cooling temperature can be customized as per customer’s needs. •The micro computer ...
Maximum temperature: -40 °C - 120 °C
... temperature operation The battery pack liquid cooler is specially used for thermal and fluid mechanics testing of liquid cooled battery packs. According to the requirements of the ...
Maximum temperature: -40 °C - 85 °C
Pressure: 0 bar - 3 bar
... temperature damage/start/operation The battery liquid cooler is specially used for thermal and fluid mechanics testing of liquid cooled battery packs. According to the requirements ...
Maximum temperature: -40 °C - 120 °C
... temperature damage/start/operation The battery liquid cooler is specially used for thermal and fluid mechanics testing of liquid cooled battery packs. According to the requirements ...
... radios, TVs and household appliances. SISE Heat & Cool systems have single and dual circuit versions and work using water, pressurized water or oil. SISE technology meets the heavy demand for « Piano ...
... 330mm Tank capacity: approx. 4l Water column: 35m | 5l/min. Cooling capacity: 1000W (1l/min.) Package includes: - Water cooling unit - Connection cable inverter / water cooling ...
Water cooling unit EVO Cool Water cooling unit for use with the EVO 200 WP or LITE controller and Tetrix 200 in conjunction with water-cooled welding tools.ols. - Standalone or continuous ...
Maximum temperature: 100 °C - 550 °C
Pressure: 20 bar - 280 bar
The ADCA sample coolers were specially designed to cool samples of boiler water or steam for analysis. Sample coolers prevent steam flashing-off from hot pressurised liquid ...
Maximum temperature: 400, 450 °C
Pressure: 110, 90 Pa
The ADCAPure SC32P sample cooler consists in a helical-coil heat exchanger used to take samples quickly and safely from steam generators, clean or pure steam systems, WFI and other high purity mediums. Its spiral design ...
... to the many industrial needs, SIMACO - leader in the fluid moving technology - designed a dedicated range of close loop air-water cooling units, where the SIMACO pump, actual beating heart, is naturally assembled. This ...
Maximum temperature: 3 °C - 5 °C
... spots, etc. • It can be also used for dust suppression, static charge prevention, and humidification. *1) Spray capacity at a water pressure of 5.0 MPa when the number of installed nozzles is 8 pcs. The number of installable ...
... at tap water pressure of 2 kg/c㎡ (0.2 MPa). It varies by the tap water pressure. 4.8 L/hr at 3 kg/c㎡ (0.3 MPa) tap water pressure, 5.1 L/hr at 3.5 kg/c㎡ (0.35 MPa) tap water ...
Maximum temperature: 3 °C - 5 °C
... capacity for each nozzle at tap water pressure of 3 kg/c㎡ (0.3 MPa) when 6–7 nozzles are installed. Spray capacity varies depending on tap water pressure and the number of nozzles. Spray capacity for ...
... With our cooling water recoolers you can pre-select the desired temperature. This guarantees that it remains constant, which increases the service life of your tools. Our recooling systems also represent a closed ...
... voltage protection, compressor protection, motor overload, overheating protection, anti-freezing protection, cold water, cooling water break water protection, temperature sensing type ...
Power: 25.7, 9.45, 19, 5.81 kW
Maximum temperature: -15, -10 °C
Flow rate: 48 l/min - 181 l/min
Chiller can be used in the Complete Egg Processing Line. For the needs of the pasteurizers, every chiller must come with OPZL option (for cooling up to -15℃) How it works: In the cooling section, ...
Power: 0.05 W - 1,470 W
Flow rate: 200 l/h - 4,000 l/h
The HC Chiller series has been specifically designed to cool or heat water for large hydroponic and aquatic systems. Integrated with on board electronic digital display the HC series is ideal for accurate temperature ...
CHARLES AUSTEN PUMPS LTD / BLUEDIAMOND PUMPS INC
Power: 1.7 kW - 58.3 kW
Maximum temperature: 25 °C
... With a non-ferrous hydraulic circuit, Hyperchill Plus is suitable for cooling low viscosity cooling fluids including water and water-glycol mixtures. Hyperchill Plus ensures stable working conditions ...
Parker Industrial Gas Filtration and Generation Di
Power: 230, 330 W
Flow rate: 2.2, 2.6 l/min
•High cooling capacity (200 kj/min) • No priming water required Cascade pump eliminates the need for priming water. •Easy maintenance No tocls are required to replace coolant. Tank and fille^ are easily ...
Flow and Temperature Control throughout the Plant The BAADER 1750 Spiral Chilling Tanks are specially designed for various applications inside the processing facility. This can include bleed-out and chilling after the BAADER 101 Harvesting ...
Water cooler designed to integrate with the Dynasty 210/300 and Maxstar 280 models.
Our FTNON Water Belt Cooler is designed to spray water over the product to provide optimal heat transfer and homogeneous cooling. FEATURES & BENEFITS • - Sprays over the entire surface ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining