ACMO tilting disc check valves are installed in pumping applications to prevent backflow in the system. All interior parts are stainless steel or coated with drinking water approved epoxy. Measures are available to mitigate pressure surges like a lever and a weight fitted to the shaft end to help close the valve before the flow changes direction.
STANDARDS OF MANUFACTURE
EN 1074-3 CHECK VALVES
EN 558 S14 (DIN 3202 F4) FACE TO FACE
EN 1092-2 DRILLING FLANGES
MATERIALS
BODY EN GJS-500-7 DUCTILE IRON EN 1563
DISC EN GJS-500-7 DUCTILE IRON EN 1563
STEM AISI420 STAINLESS STEEL EN 10088-3
BUSHES BRONZE EN 1982
ARM AND COUNTERWEIGHT
FIG.221-221A-222 – EN GJS-400-15 DUCTILE IRON EN 1563
FIG.F221-F221A-F222 – S355JR CARBON STEEL EN 10025
CORROSION PROTECTION
COATED INSIDE-OUTSIDE
EPOXY 250 MICRONS
CERTIFIATES
D.M. NR.174 – HEALTH DEPARTMENT (I)
TESTING
EN 12266-1 (ISO 5208) PRESSURE TESTS
GRADE “A”