Transport calibration system
pressurekit

Transport calibration system - ACRN - pressure / kit
Transport calibration system - ACRN - pressure / kit
Transport calibration system - ACRN - pressure / kit - image - 2
Transport calibration system - ACRN - pressure / kit - image - 3
Transport calibration system - ACRN - pressure / kit - image - 4
Transport calibration system - ACRN - pressure / kit - image - 5
Transport calibration system - ACRN - pressure / kit - image - 6
Transport calibration system - ACRN - pressure / kit - image - 7
Transport calibration system - ACRN - pressure / kit - image - 8
Add to favorites
Compare this product
 

Characteristics

Physical quantity
pressure, transport
Options
kit
Pressure

Min.: 0 bar
(0 psi)

Max.: 6 bar
(87.02 psi)

Description

The calibration test, associated with a tube weld tester, allow to mesure the internal pressure of a tube subjected to the application of a crushing pressure exerted by the compressiometer Why use a calibration kit ? Each tube is defined by several parameters such as his fill rate, his diameter, his volume or his material. The variation of one of these parameters, for a similar crushing pressure, named “external”, cause a variation of the internal pressure of the tube, this latter revealing the real resistance of the tube weld. In addition, it was more pertinent to refer to this internal pressure. It has to fix a restricted internal pressure meeting the most probable requirements, namely that the tube does not explode under normal use, and that it withstands transport constraints. Description Strengths of kit: The use of this Kit is a revelant prerequisite for setting up a test (protocol validation, creation of abacus, observation of physical phenomena, etc.) beacause it makes it possible to correlate the compression tube value with its internal pressure ACRN can provide with the delivery of the system, an abacus validated during these years of experience. Operation You just have to open the valve to fill the water pipe. During the external effort, a pressure balance is then created between the water and the product, pressure reported at the level of the manometer, protected by a water membrane during compression. Benefits Establishment of a reliable weld resistance test protocol according to transport requirements Adaptable to all types of samples Adapted to the production envrionment / Robust Many different pressers to reach the target internal pressure

Catalogs

No catalogs are available for this product.

See all of ACRN‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.