Industrial Weighing
Intrinsic safety FM certified
All stainless steel, suitable for harsh industrial applications
Interchangeability 0.25% for multiple load cell applications
5-point traceable NIST calibration
Technical informations
Excitation -
10 Vcc (15 Vcc max)
Output -
3 mV/V ± 0,25%
5 points Calibraion -
0 %, 50 %, 100 %, 50 %, 0% in compression
Models ordered with the optional board are calibrated in voltage.
Linearity -
0,10 % of the full scale output
Hysteresis -
0,10 % of the full scale output
Repetability -
0,05 % of the full scale output
Zero balancing -
± 1 % of the full scale output
Certification -
Intrinsinc safety FM IS/I.II.III/1/CDEFG
Safe overload -
150 % of capacity
Ultimate overload -
300 % of capacity for models ≤ 400 000 lb;
200 % of capacity for models > 400 000 lb
Bridge resistor -
350 ± 10 Ω
Full scale deviation -
0,025 à 0,075 mm (0,001 à 0,003") typical value
Construction -
Stainless steel 17-4 PH