Normal-beam dual-crystal ultrasonic transducer for transmitting and receiving the longitudinal ultrasonic waves
The ultrasonic dual crystal transducer D1762 is used to perform wall thickness measurements and ultrasonic flaw detection in metallic, plastic and composite materials by transmitting and receiving ultrasonic longitudinal waves. The transducer can be used as a part of ultrasonic thickness gauges and flaw detectors in pulse-echo mode.
The transducer can be driven by the following ACS instruments:
• A1212 Master
• A1214 Expert
• A1550 Introvisor
• A1525 Solo
• A1560 Sonic-HF
Type of transducer - dual element, piezoelectric
Type of generated wave mode - Longitudinal
Nominal frequency - 5 MHz
Effective transducer aperture diameter - 12 mm
Piezo-element electric capacity - 1500 ± 150 pF
Maximum excitation pulse voltage, V - ± 250 V
Operating temperature range - –30...+50°C
Connector type - 2 x LEMO00.250
Dimensions - 23 × 44 × 15 mm
Weight - 22 g