With high quality ,this double ended shear beam load cell is widely used in chemical engineering,food,etc Anti-side force structure enables this double ended shear beam load cell to be used for hopper scales in hostile environments with shocks,reverse,etc.
Rated Output(mV/V) 2.00±0.005
Nonlinearity ±0.02%FS
Hysteresis ±0.02%FS
Repeatability ±0.01%FS
Creep(30 minutes) ±0.02%FS/10℃
Zero Balance ±1.00%FS
Temperature Effect on Zero ±0.02%FS/10℃
Temperature Effect on Output ±0.02%FS/10℃
Input Resistance(Ω) 770±15
Output Resistance(Ω) 700±5
Insulation Resistance ≥5000MΩ
Excitation Voltage 10V(DC/AC)
Compensated Temperature Range -10℃~+50℃
Operating Temperature Range -20℃~+60℃
Safe Overload 120%FS
²Cable Φ5.4×6m
Cable Color Code Input:Red(+) Black(-)
Output:Green(+) White(-)