he pilot pressure regulator/booster regulates the outlet
pressure through a signal pressure at ratio of 1 to 1.
Functioning as a pressure regulator the pilot pressure may
either be internally inducted from the inlet pressure or
externally. The dome chamber is closed by a needle valve.
Functioning as a volume booster the dome is controlled by
a proportional pressure regulator or a pilot pressure regulator.
Media: compressed air, non-corrosive gases or liquids
Pilot_port: G1/4
Accuracy:
at supply pressure variation of 10 bar = 0.1 bar pressure deviation
at temperature variation of 3 °C / K = 1% pressure deviation at internal pilot pressure
Air_consumption: without constant bleed
Relieving_function: non-relieving
Gauge_port: not available
Mounting_position: any, dome preferably mounted up
Body: brass or stainless steel
Inner_valve: brass or stainless steel
Elastomer: FKM, optionally EPDM