The air amplifier compresses air or nitrogen from a standard
pressure of 10 bar max. to the desired outlet pressure of
60 bar max. This is realised by cylinders with different ratios
- simple, safe and economical. No electrical installation is
required and there is no energy consumption once the final
pressure has been reached. Service life 3 million cycles, full
load operation 12 min max. per hour.
Media: lubricated, unlubricated and 50 µm filtered compressed air or nitrogen
Mounting_position: any
Power_device:
Cylinder with integrated reversing valve, check valve and silencer.
The pressure will be increased selective to the consumer. No energy
consumption once final pressure is attained.
Drive_pressure_PA: system air to drive the air amplifier, 2…10 bar
Supply_pressure_P1: max. 12 bar, for instance nitrogen or compressed air
Outlet_pressure_P2: amplified outlet or operating pressure of 20 bar to 100 bar maximum
Continuous_operation:
20% of the diagram values should maximally be realised at permanent running
Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F
Sound_level: max. 79 dB (A)
Body: aluminium
Seals: NBR/Buna-N