The interpolation unit (IPE40) is used to increase the resolution of incremental distance and angle measuring systems with sinusoidal output signals that are phase-shifted by 90 °. It is suitable for sensors with a standardized voltage or current interface. An adjustable minimum edge distance at the output as well as the programmable analog and digital hysteresis enable use even with impaired input signals.
- Input signals -
Sine / cosine / reference signal
Differential / single-ended
Adjustable gain for 1Vpp / 660mVpp / 530mVpp / 80mVpp
Maximum 1.2MHz for interpolation rates ≤ 20
Maximum 750kHz for interpolation rate = 32
Maximum 600kHz for interpolation rate = 40
- Interpolation rate
40 / 32 / 20 / 16 / 8 / 4 Edges per sine period
- Zero signal processing -
Adjustable width of the reference signal at the output
- Interference suppression -
Adjustable hysteresis analog
Adjustable hysteresis digital
Adjustable minimum edge separation at the output