Zero migration volume
Maximum zero positive migration volume: difference between migration volume upper range and measuring range
Maximum zero negative migration volume: lower than air pressure
Measuring range
Lower range limit:-100%URL (≥-0.1%MPa)~ +100%URL-Span
Upper range limit:-100%URL+Span (≥-0.1%MPa+ Span)~+100%URL
Measuring range and zero adjustment
HART manipulator, local button, HART protocol
supported by communication software.
Measuring object: liquid, vapor and gas
Ambient temperature: -40℃ ~ 85℃
Accuracy: 0.1% F.S
Range ratio: 100:1
Insulation resistance: >100MΩ (500VDC)
Damping value: 0.1~16s (Optional)
Temperature affecting value: better than 0.1%F.S/10℃
EMC: EN 61326-1:2013
Output signal: 4~20mA(Max 22mA,Min 3.8mA)
Communication interface: HART
Intrinsic safety: EX ia IIC T6