video corpo

Temperature monitoring system LD1200
conditionconcentrationmeasurement

Temperature monitoring system - LD1200 - AnHui Wanyi Science and Technology Co., Ltd. - condition / concentration / measurement
Temperature monitoring system - LD1200 - AnHui Wanyi Science and Technology Co., Ltd. - condition / concentration / measurement
Temperature monitoring system - LD1200 - AnHui Wanyi Science and Technology Co., Ltd. - condition / concentration / measurement - image - 2
Add to favorites
Compare this product
 

Characteristics

Type
temperature, condition, concentration
Applications
measurement, emissions, particle, dust, gas

Description

LD1200 is a highly sensitive device with robust design. It is provided with the high-temperature extraction sampling system scheme as well as the principle of laser forward scattering to measure particulate matters with high humidity and low concentration in the flue. It is suitable for measuring soot emissions with low temperature and humidity where the wet dust collectors are assembled and the flue gas temperature is below zero (including liquid droplets). This method effectively eliminates the interference of water vapor in the flue gas on the measurement of particulate matter. As the principle of the laser forward scattering method is adopted, the sensitivity of low-concentration measurement is high. The core component of LD1200 system is a light scattering sensor, of which the particulate concentration can be accurately measured to 0.1mg/m³, the certified range is 0-15mg/m³, and the extended range can reach 100mg/m³. The forward scattering sensor has a narrow forward scattering angle, so that the effect of particulate type and refractive index can be minimized. Performance characteristics 1. The optical structure has the laser forward scattering method with ultra-low range and ultra-high sensitivity, and the lowest testing limit is 0.1/m³. 2. It is provided with advanced high-temperature extraction sampling and high-temperature analysis measurement, which is not affected by moisture. 3. The zero point and range can be automatically calibrated, and the operation is stable and reliable. 4. The purging system can clean the sampling pipeline and optical testing parts regularly, so that the maintenance workload is low_ x000D_.

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.