DIN rail mount temperature transmitter AR592
RTDthermocouple2-wire

DIN rail mount temperature transmitter
DIN rail mount temperature transmitter
Add to favorites
Compare this product
 

Characteristics

Mounting
DIN rail mount
Input type
RTD, thermocouple, 2-wire, 3-wire
Output signal
analog, 4-20 mA
Other characteristics
programmable, galvanically-isolated

Description

• linear conversion of the measured temperature or other measure into a current signal • input (programmable): - resistance: 0÷2500 Ω • input type, processing range and other processing parameters configured with AR950, AR956 programmer or AR956 programming set or by the manufacturer according to customer specifications • processing range: any in the input measuring range • signalling the exceeded processing range or sensor error: • optical: red LED • output: 3.8 or 21 mA • galvanic separation (input / output) • housing for mounting on DIN35 strip • high accuracy and immunity to interference • power supply: 10 ÷ 36 Vdc • response time (10÷90%): 360ms, programmable in the range of 240÷1600ms • separation: 1.5 kV, 50 Hz, 1 min • operating temperature range: 0 ÷ 65 °C • relative humidity range: 0 ÷ 90 % (no condensation) • ingress protection rating: IP20