Air analyzer ZCO
COprocesstoxicity

air analyzer
air analyzer
air analyzer
Add to favorites
Compare this product
 

Characteristics

Measured entity
CO, air
Application domain
process
Measured value
toxicity, temperature
Configuration
in situ
Technology
optical
Other characteristics
calibration, sampling

Description

The in situ analyzer of the cross-stack type is able to perform the average measurement of carbon monoxide over the entire section of the chimney. With no parts in contact with the process and with only the presence of the barrier air, it ensures long-term reliability, stability and accuracy. Thanks to the “in situ” installation, that is, directly on the chimney, it does not require a gas sampling and treatment system, with a significant reduction in the costs of basic equipment, installation and maintenance. FEATURES - VALUES Measuring range - programmable from 0-500 ppm to 0-20.000 ppm relative to 1 m of optical path Optical path - up to 2500 mm Accuracy - 5% f.s. Smoke temperature - ≤ + 250 ° C (with extended calibration max ≤ + 430 ° C) Visualization - in ppm, mg/m3 and mg/Nm3 Certification - TUV
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.