Characteristics

Type
signal
Secondary function
switching
Other characteristics
digital, analog, programmable, with RS-485 interface, for strain gauge sensors
Voltage

Max.: 10 mV

Min.: 0 mV

Current

20 mA

Description

• - Amplifier with integrated overload protection • - Input: 4x strain gauge • - Output: 2x standard signal; digital bus systems • - 8 digital switching outputs in accordance with EN ISO 13849-1 Applications The amplifier with integrated overload protection SLS 801 is used in machines and systems for monitoring and comparing the output signal. The control system is built with 100 % redundancy as well as diversity for the critical safety function. Exceeding programmable signal limits will be generating digital fault signals. Special features • - Protection: EN ISO 13849-1: available for performance level PLd • - Sensor inputs: 2x2 Strain gauge Sensors or 2x2 4...20mA-Sensors (also 2-wire) • - Digital inputs: 16 channels optically isolated • - Analog outputs: 2x 4...20mA or 2x 0-10V • - Output control panel: 8x DC1: 24V/2A • - Interfaces: LAN X1: RS485 / RS232 optional X2: CAN