Application
RRU, AAU, BBU power transmission between PCB
Product Introduction
Strength conduction capacity;
Design by different needs like leave some holes blank or change the contact arrangement;
Products comply with RoHS requirements;
Apply to tele-com power equipments;
Technical Parameter
Rated current -
12V Power:92A/Pin * 6Pin
48V Power:10A/Pin * 2Pin
Signal:1.5A/Pin * 30Pin
Rated voltage -
12V Power:60V DC
48V Power:200V DC
Signal:48V DC
Insulation resistance -
Power:≥10000 MΩ
Signal:≥5000 MΩ
Contact resistance -
12V Power:1mΩ Max
48V Power:5mΩ Max
Signal:20mΩ Max
Withstand voltage -
Power:2500V DC
Signal:500V DC
Vibration and shock - 10-500-10Hz, accelerated speed 490m/s2
Endurance (Cycle) - 250
Salt spray -
48h(5% concentration), no corrosion