IEC 60870-5-104 remote terminal unit DB RTU M4
GPRS4GModbus RTU

IEC 60870-5-104 remote terminal unit - DB RTU M4 - Bausch Datacom - GPRS / 4G / Modbus RTU
IEC 60870-5-104 remote terminal unit - DB RTU M4 - Bausch Datacom - GPRS / 4G / Modbus RTU
IEC 60870-5-104 remote terminal unit - DB RTU M4 - Bausch Datacom - GPRS / 4G / Modbus RTU - image - 2
IEC 60870-5-104 remote terminal unit - DB RTU M4 - Bausch Datacom - GPRS / 4G / Modbus RTU - image - 3
IEC 60870-5-104 remote terminal unit - DB RTU M4 - Bausch Datacom - GPRS / 4G / Modbus RTU - image - 4
Add to favorites
Compare this product
 

Characteristics

Type
GPRS, 4G, Modbus RTU, Modbus TCP
Port
Ethernet, RS-485
Other characteristics
wireless, IEC 60870-5-104, modem, router

Description

SCADA IEC 60870-5-104/Modbus Workhorse! - LTE Cat1 with GPRS fallback RTU The DinBox RTU M4 is a low-cost micro RTU with built-in wide range AC power supply. The power supply comes with a supercap back-up, in order to ensure the required energy to communicate with the SCADA system, even after a mains power supply disconnect. Direct WAN communication is possible thanks to the built-in Sierra Wireless communication module. Everything is managed by a powerful Cortex M4 microcontroller. Finally, the RTU is built into a DIN rail mountable housing. The DinBox RTU M4 uses IEC 60870-5-104 to communicate as a slave with the SCADA system (master). Other protocols such as MQTT can be implemented. The DinBox has 8 active digital inputs, which enable sending events when a change has been detected. Furthermore, it has 2 digital outputs which can be controlled via SCADA commands, and 2 analogue inputs to monitor. Thanks to the modbus master implementation and the modbus-to-IEC104 mapping the DinBox RTU M4 can be used as a gateway to connect other modbus slave IEDs. Authentication, integrity and security are provided per application or service running on the RTU by protecting the transport layer of the protocol stack with TLS (Transport Layer Security). Highlights GPRS/LTECat.M1 Communication IEC 60870-5-104/Modbus mapping Backend Services FoTa / Commissioning / Security / Remote parametrization... I/O Ethernet Routing TLS Security Supercap ‘Last gasp’ Applications: Substation IP communication with SCADA systems or central dispatch IEC-60870-5-104 protocol between substation and control station

Catalogs

No catalogs are available for this product.

See all of Bausch Datacom‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.