B_23074 test bench is designed to set and hold pressure into water – glycol circuits that are subjected to variation of temperature.
Connection system is made by 4 manifolds in order to connect 2 different heat exchangers.
Working steps:
• Connect UUT on test bench:
• Flush and releases air;
• Set working pressure and maintenance time;
• Start, stop and empty circuit.
• Pressure: < 3,2 ± 0,1 bar
• Temperature: -40 < T < 120 °C
• Reacting time: < 0,5 sec
• Stability: < 0,5 %
INSTRUMENTATION:
• Pressure transmitter: 0 ÷ 6 bar ; cl. 0,25%
SAFETY DEVICES:
• Open doors interlock
• Emergency mushroom button
• Test shuts down if component failure, oil leakage or test bench warning
• Overpressure safety valve
POWER SUPPLY:
• Electric: 230 Vac-50hz-3kW
• Air: 6 bar
DIMENSIONS AND WEIGHT:
• L, p, h (chamber): 600 x 1200 x 1500 mm;
• Raw load: ~ 130 kg
COLORE:
• Standard Gray 7035 / White 9010