ACB SERIES •
Amplified in a.c. 3 wires + earth •
Cable output •
General Features:
These sensors have two wires for power supply and one for the output. They are
able to drive very low current loads such as some kind of PLC with A.C. inputs.
Technical data:
• Supply voltage (UB): 20 ÷ 240 Vac
• Electrical system frequency: 40 ÷ 60 Hz
• No-load supply current (Io): ≤ 4 mA
• Minimum operational current (Im): 0,5 mA
• Voltage drop (Ud): ≤ 3 V
• Max thermal drift of sensing distance Sr
: ± 10%
• Repeat accuracy (R): 2%
• Switching hysteresis (H): 10%
• Degree of protection: IP67
• Switch status indicator: yellow LED
• Cable conductor cross section: 0,75 mm2
• Suppression of initial false impulse
• Electromagnetic compatibility (EMC) according to EN60947-5-2
• Shock and vibration resistance according to EN60068-2-27 EN60068-2-6
Materials:
• Cable: 2 m PVC
• Housing: nickel plated brass
• Sensing face: plastic