• Degree of protection IP68
• Amplified in a.c. 2 wires
• Cable output
General Features:
This new series solves definitively the problem of the ingress of liquids to the inner
parts of the sensors. Thanks to the inner hermetic sealing they can be submitted to nostop jets of liquids under pressure even in presence of temperature changes.
They find application in automatic washing machinery, in machines subject to water
jets and in continuous immersion applications.
Technical data:
• Supply voltage (UB): 20 ÷ 240 Vac
• Electrical system frequency: 40 ÷ 60 Hz
• Off-state current (Ir
): ≤1,5 mA at 110 Vac
• Minimum operational current (Im): 5 mA
• Voltage drop (Ud): ≤ 5 V
• Max thermal drift of sensing distance Sr
: ± 10%
• Repeat accuracy (R): 2%
• Switching hysteresis (H): 10%
• Degree of protection: IP68
• Switch status indicator: yellow LED
• Cable conductor cross section: 0,50 mm2
• Suppression of initial false impulse
• Class 2 equipment according to IEC 536
• Shock and vibration according to EN60068-2-27 EN60068-2-6
• Electromagnetic compatibility (EMC) according to EN60947-5-2
Materials:
• Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R.
• Housing: plastic
• Gland: nickel plated brass
• Sensing face: plastic