These sensors are completely electronic and detect the position of the magnetic ring inside a standard pneumatic cylinder with a T slot. The sensor remains completely recessed and thus mechanically protected. A clip to fix the cable inside the slot is supplied with the sensor. Main advantages of static output sensors are unlimited electric life, protection against short circuit and line transients, high switching frequency and no contact bounce. Version with output holding function available on request. A yellow LED gives indication of the output status. Available with cable exit, M8x1 connector or M12x1 connector.
Technical data:
• Supply voltage (UB): 10 ÷ 30 Vdc
•No-load supply current (Io): < 10 mA
• Switch status indicator: yellow LED
• Cable conductor cross section: 0,15 mm2
• Electromagnetic compatibility (EMC) according to EN60947-5-2
• Protected against short circuit, overload and connection mistakes
• Shock and vibration resistance according to EN60068-2-27 EN60068-2-6
Materials:
• Cable: BMT... PVC CEI 20-22 II; 90°C; 300V BMT...F; BMT...N; BMT...H; BMT...R PUR VDE 0492/265 90°C
• Sensor and fixing clip: plastic
• Rotating nut and fixing screw (*): nickel plated brass (*) Stainless steel fixing screw available on request