• SHORT SERIES
• Amplified in d.c. 3 wires
• Cable output
Technical data:
• Supply voltage (UB): see ordering references
• Max ripple: 10%
• No-load supply current (Io): ≤ 10 mA
• Voltage drop (Ud): ≤ 1,5 V
• Temperature range: - 25° ÷ + 70°C
• Max thermal drift of sensing distance Sr
: ± 10%
• Repeat accuracy (R): 2%
• Switching hysteresis (H): 10%
• Switch status indicator: yellow LED
• Cable conductor cross section: 0,22 mm2 on 6,5 and 8 mm
0,35 mm2 on 12 mm
0,50 mm2 on 18 and 30 mm
• Protected against short-circuit and overload
• Protected against any wrong connection
• Suppression of initial false impulse
• Electromagnetic compatibility (EMC) according to EN60947-5-2
• Shock and vibration resistance according to EN60068-2-27 EN60068-2-6
Materials:
• Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R.
• Housing 6,5 and 8 mm: stainless steel
• Housing 12 ÷ 30 mm: nickel plated brass
• Sensing face: plastic