Off-grid DC/AC inverter BFI-P2-42-0240-3F4N-MN
poweradjustablefrequency

Off-grid DC/AC inverter - BFI-P2-42-0240-3F4N-MN - Beijer Electronics - power / adjustable / frequency
Off-grid DC/AC inverter - BFI-P2-42-0240-3F4N-MN - Beijer Electronics - power / adjustable / frequency
Add to favorites
Compare this product
 

Characteristics

Type
off-grid
Electrical characteristics
power, adjustable, frequency, synchronous, analog, brushless, AC, DC, three-phase, PWM
Applications
for industrial applications
Other characteristics
compact
Certifications
IEC
Power

5,500 W

Output voltage

230 V

Voltage

Min.: 200 V

Max.: 240 V

Primary current

24 A

Description

IP55 General description Warranty - 2 year Mechanical IP class - IP55 Physical size - Size 4 Measurements (H x W x D) - 450 mm x 171 mm x 252 mm Weight - 12 kg Typical power loss at rated power - 2 % of rated power Main switch - Yes, as option Built in Main switch, control switch and potentiometer - No Conformal coated PCBs - Yes, IEC 60721-3-3, 3S3/3C3 Output ratings Overload capacity - 150% for 60 seconds, 200% for 4 seconds Output frequency - 0 – 500Hz, 0.1Hz resolution Supported motor types - 3 phase AC induction (IM), AC permanent magnet (PM), Brushless DC (BLDC), Synchronous reluctance (SynRM) Built-in brake transistor - Yes Regenerative capacity - 100 % ED Input ratings Voltage fluctuations - +/- 10% Phase imbalance - 3% maximum allowed Displacement factor - > 0.98 Supply frequency - 48 – 62Hz Power cycles - 120 per hour maximum, evenly spaced Control specification Control modes - V/F Voltage Vector, Energy Optimised V/F, Sensorless Vector Speed Control, Sensorless Vector Torque Control, Synchronous Reluctance Motor Control, Brushless DC Motor Control, Closed Loop (Encoder) Speed Control, Closed Loop (Encoder) Torque Control, Open Loop PM Vector Control Current/torque limitation - Torque and current limitation PWM frquency - 4-32 kHz effective Stopping mode - Ramp to Stop: User Adjustable 0.01 – 600 seconds, Fast stop, Coast to Stop Braking - Motor Flux Braking, Built-in Braking Transistor Skip frequency - Yes Analog setpoint control - 0 to 10V, 10 to 0V, −10 to 10V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.