Voltage calibrator EJB 9970
currentcompact

Voltage calibrator - EJB 9970 - BERCU - current / compact
Voltage calibrator - EJB 9970 - BERCU - current / compact
Add to favorites
Compare this product
 

Characteristics

Physical quantity
voltage, current
Options
compact
Temperature

Max.: 55 °C
(131 °F)

Min.: -10 °C
(14 °F)

Voltage

Max.: 100 mV

Min.: 20 mV

Description

EJB 9970 Volt / mA CALIBRATOR The EJB 9970 Volt/ mA Calibrator for measuring 0 to 24 mA DC current loop (with very high accuracy of 0,015%) or 0 to 20 V DC voltage, it delivers outstanding performance, durability and reliability. With a push button EJB 9970 is easy to use. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. It is compact, lightweight, and easy to carry. Display : large (64 x 42 mm) 5 digit LCD DC voltage input & output : 0-100,00 mV DC voltage accuracy : ± 0,02% + 3 counts DC current input & output : 24,000 mA DC current accuracy : ± 0,015% + 3 counts Loop power output 24V ± 10% Input impedance : 2M Over voltage protection : 30V Voltage driver capability : 1 mA Fuse : 125 mA / 250 V fast acting fuse External power operation Dimensions : 205 x 97 x 45 mm Weight 460 g (incl. battery)

Other BERCU products