Length "L" of the gearmotor as a funtion of reduction and output number of revolution with the standard motor
756 L 90 output W 3200 Rpm loadness, 12 or 24 Vdc. Starting corrent 22 A. (42A x 12 Vdc)
Output shaft is supported by two coupled screened bearings.
The motor has an electrical suppressor system for the CE standard.
The motor and the reduction gear are both plated for corrosion strength.
Connecting 2 wire 0,75 x 250 mm.
*The speed rotation can change of ±10%.
The S1 load test was made using a (3A) corrent in the air with an increase of temperature of 70° C.
The S2 test was made using a (7 A) corrent in the air with a 50% timing 5' with an increase of temperature
of 80° C max. The starting corrent is (I max) and cannot be mantained for more than 2".
Max forces which may act on the output shaft: Axial 200 N, Radial 300 N on the extremity of output shaft.
It is possible to apply an encoder