Length "L" of the gearmotor as a funtion of reduction and output number of revolution with the standard motor
752 40 output W 2900 Rpm loadness, 12 or 24 Vdc. Starting corrent 7 A. (14A x 12Vdc)
Drivingshaft supported by self lubrificating bushings. Output shaft supported by two coupled screened bearings.
The motor’s surface and reducer’s surface are both plated to avoid corrosion.
The motor has an electrical suppressor system for the CE standard.
Connecting wires 0,75 x 250 mm.
*The rotation speed can change of ±10%.
The S1 load test was made using a (1,5 A) corrent in the air with an increase of temperature of 70° C.
The S2 test was made using a (2,8 A) corrent in the air with a 50% timing 5' with an increase of temperature of 80° C max.
The starting corrent is (I max) and must not maintained for more than 2".
Max load on the extremity of output shaft: Axial 300 N, Radial 400 N
It is possible to apply an encoder.
Possibility to apply other motor.