A single action manual piston pump used to actuate fixed output positive displacement oil injectors.
The unit can be used with series ZJB, ZMB, ZT and SJM injectors. The pump incorporates an internal
maximum pressure relief valve and a flow control valve to relieve distribution line pressure as
required for normal operation of positive displacement oil injectors. Models are offered with a
delivery connection outlet on left or right sides of the unit. A dual outlet (left and right sides) is
also available.
Operation
For a delivery stroke, pull the handle firmly and briefly to its lower end position. This action builds up
system pressure to actuate injectors. To depressurize pressure in the system, return handle to its
original upright position.
If main line distribution is 2 meters (6 feet) or longer, use 6 1/4” O.D. tubing or larger diameter
tubing. The oil demand of the PDI system should not exceed 75% of the full volume oil output from
pump to allow sufficient capacity for system pressure build-up.