Our Series 700 Temperature Switch are designed to compliment the extensive Series 700 Pressure and DP switches.
Series 700 Temperature Switches offer accurate, reliable switching in a robust cast enclosure.
Scale Accuracy & Setpoint Calibration:
A 0-100% scale is fitted to all switches and provides anapproximate indication of the setpoint relative to therange of the switch. The scale is not intended for precise calibration purposes. For precise calibration the scales hould be used for initial guidance and the final adjustmen tmade against an instrument sufficiently accurate to meet the site requirements.
Combined Switching Errors & Maximum Working Temperature (MWT):
The sum of the average switching errors and the operating value repeatability will typically not exceed 0.3% of range span, at setpoints of 10%, 50% and 90% of span.
The maximum working temperature of the temperature element is detailed in the range table.
Reset (Switching Differential):
There may be some variation in the reset throughout the range of the switch. The figure quoted on page 1 of this data sheet is the basic switching differential value expressed as a percentage of the span at a mid range setpoint.