Shielded pairs railway signaling cables, armoured PE sheath with a 0,1 RF, ADIF standard
Cables of 1 to 20 pairs individually shielded with an aluminium/polyester laminate. Conductors of 0.9 and 1.4 mm nominal diameter, PE insulation. Pairs are stranded in layers to form the core that is protected with a polyethylene anti-inductive sheath with a reduction factor of 0.1. They are used as signalling cables in railways infrastructures where protection against power lines induction is required. For installation in ducts or directly buried. Protected against rodents
Signaling cable
Impact Resistant
UV Resistant
Rodent resistant
EMI protected
ROHS Compliant'
STANDARDS
Construction. ADIF ET-03.365.051.6
CONSTRUCTION
Conductors: Annealed copper, 0.9 and 1.4 mm of nominal diameter.
Insulation: Solid polyethylene.
Cabling elements: Shielded pairs with an aluminium/polyester tape. Continuity tinned wire under the tape.
Core formation. Stranded in layers. Colour code as per ADIF ET-03.365.051.6.
Core wrapping: Dielectric tape longitudinally applied with overlap.
Cable screen. Bare copper conductors helically applied.
Inner sheath: Polyethylene.
Armour: Two 0.8 mm thick steel tapes helically applied.
Outer sheath: UV resistant black polyethylene.
Sheath marking: The outer sheath shall be marked in white ink, at regular intervals, with the following information:
o Name of manufacturer/ Year/ Length marks
o Other type of marks according to the costumer