Quaded railway signaling cables, armoured PE sheath with a RF 0,1 RF, TCDD standard
Cables from 1 to 27 quads star, conductors of 0.9 mm with polyethylene insulation. Quads are stranded into layers to form the core which is protected by an anti inductive sheath with reduction factor of less than 0.1. They are used as telecommunication cables or in rail circuits, especially in rail infrastructures, when protection is required against the induction of high voltage lines. For installation in ducts or directly buried. The cable is rodent resistant.
Telecommunication cable
Impact Resistant
UV Resistant
Rodent Resistant
Resistant to EM interferences
ROHS compliant
SPECIFICATIONS
TCDD
CONSTRUCTION
Conductors: Grade A. Plain Annealed solid copper wire, nominal diameter 0.9mm (0.63 mm2).
Insulation: HDPE, acc to EN 50290-2-23.
Cabling element: Star quads coloured acc. to Table 1.
Core formation. Stranded in layers. Acc. To Table 2.
Core wrapping. One or more Polyester tapes.
Bedding: Polyethylene, acc. to EN 50290-2-24.
Cable screen. Two helically applied copper tapes with a thickness of 0,4 - 0,6mm. each.
Intermediate sheath: Polyethylene acc to EN 50290-2-24.
Armour: Two helically applied steel tapes with a thickness of 0.8 – 1.0 mm each.
Outer sheath: UV resistant black polyethylene acc to EN 50290-2-24.
Sheath marks : The sheath shall be marked, at a regular intervals, with the following information
o Cable type (example: 3x4x0.9mm)/Manufacturer
(CABLESCOM)/TCDD/Manufacturing lot/Length markings in meters(tolerance ± 1%).
o Other marks available upon customer request