Characteristics

Measured entity
signal
Application domain
monitoring, process
Measured value
spectrum
Configuration
online
Technology
optical
Other characteristics
digital, multi-channel, pulse, MCA

Description

Eight independent 32k digital MCA in VME form factor Perfectly suited for high resolution gamma ray spectroscopy with single and segmented HPGe, Clover and Silicon detectors and compatible with medium-fast scintillator like NaI, CsI, BGO Software selectable coarse gain (x1, x2, x4, x8) Jumper selectable x0.2 attenuation 10 μs AC coupling jumper selectable for TRP detectors Digital oscilloscope for an easy acquistion parameters setup and signal monitoring Features Digital Pulse Processing for PHA, providing Energy and Timestamp in list mode Software adjustable digital shaping filter, baseline restoration and fine gain Online pile-up rejection and software dead time evaluation Suited also for high count rate application Configurable coincidence or anti-coincidence of the input analog signals for background rejection and anti-compton shield VME and Optical Link communication interface Drivers, libraries and API for Windows and Linux 32/64 bit MC2Analyzer and CoMPASS software to manage the acquisition and perform basic spectrum analysis Overview The V1782 is the new CAEN Octal 32k digital MCA. Designed for high energy resolution semiconductor detector is perfectly suited for those application in which the number of input channels start becoming relevant such as when segmented HPGe, Clovers and silicon detectors are involved. The V1782 provides four steps of software selectable coarse gain and two possible jumper selectable dynamical ranges (0.2-0.4-0.8-1.6 Vpp and 1-2-4-8 Vpp). It is also compatible with Transistor reset preamplifier thanks to the jumper selectable 10 us AC coupling.

Catalogs

No catalogs are available for this product.

See all of CAEN Spa‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.