In this configuration, in addition to the characteristics of the versions with solenoid valves only, the soft start function has been integrated, which allows a gradual introduction of pressure into the system.
Its positioning upstream of the solenoid valves allows, even in the event of an anomaly, to always have the maximum discharge flow rate. Thanks to the internal construction solutions it was possible to maintain the design and dimensions of the standard product, no further interface plates are necessary.
Please note: the safety valve alone is not sufficient to guarantee the safety function. Its activation requires the use of a supervisor device.
»» According to Machinery Directive 2006/42 / CE
»» Easy integration with Series MX FRLunits
»» Different solutions up to Performance Level E
»» Integrated soft start valve
»» No interface plate for connections
The Machinery Directive (MD) 2006/42 / EC establishes the safety requirements that a machine must respect in order to protect
the health of people during its use.
Series MX SAFEMAX solenoid valves comply with ISO 13849-1, regarding the safe design of control systems that perform safety functions.
Construction modular, compact, spool-type
Materials see TABLE OF MATERIALS on the following page
Mounting in-line, wall-mounting (by means of clamps)
Medium Filtered air in class 7.4.4 according to ISO 8573-1. In case lubricated air is used, we recommend ISOVG32 oil and to never interrupt lubrication.
Connection DIN EN 175 301-803-B
Voltage 24V DC (±10%) 3,1W (ED 100%)
Connection with wires, M8
Voltage 10-28V DC
Operation Magnetoresistive