This chamber is made of a cabinet that includes 3 dinstinct devices, enabling watertightness tests according to procedures described in standards of the main automobile manufacturers.
The 3 functioning modes are defined according to the wanted sprinkling type :
Nozzle mode
Ramp mode
Half Ring mode
To each mode correspond a type of test and a specific assembly of the samples to test.
The water used for the sprinkling is recycled thanks to a retention tank. Fillings and drainings are automatic.
Each different type of test is entirely piloted by the software Spirale 3 from the command unit with tactile screen.
(according to the functioning mode)
Flow rate from 0 to 5 l/min
Pressure from 0 to 10 bar