Safety Module with antivalent inputs – Suitable for control of safety limit switches and safety magnetic sensors mounted with antivalent contacts (1NO+1NC) mounted on Safety Guards.
3 NO Safety Outputs + 1 NC Signalling output
Two channel configuration useful for safety systems up to PL e (according to EN ISO 13849-1)
Safety cathegory CAT 4 (according to EN ISO 13849-1) – MTTFd 420,8 anni – PFHd 1,85 E-10 – DCavg 99%
Configurable for MANUAL START, AUTOMATIC START e MONITORED START
Plastic casing – IP20 – Supply voltage 24V AC/DC