Protective mobile device opening authorization at low temperature
INOX 316L housing
Application on industrial oven doors or any area to be protected against excessive temperature
• Mechanical cycle before failure: B10 = 1,000,000,000
• Electrical cycle before failure: B10 = 100,000 at 400 mA
• Safety Type: Positive
• Operating mode: in contact with the wall to be detected
• Activation temperature: 60°C or 90°C depending on the model
• Disabling temperature: 50°C
• Accuracy: +/- 3°C
• Safety contacts: 2 x NF 400 mA/24VDC redundant below temperature threshold
• Reset: automatic
• Attachment: 2 M4 screws not included; anti-rotation lugs provided
• Mounting position: 1 (4 x paste on screw-caps provided)
• Material: 316L stainless steel mirror polished case,
• Electrical connection: 50cm Ultra-soft silicone cord with M12 connector.
• Water resistance: IP 69K
• Temperature: -40°C to +180°C
• Marking: laser engraving with mechanical punching of the serial number for permanent traceability