Touch button access request with tricolor lighting
Detection through a glass wall or lexan
Contactless detection up to 40 mm
LED light ring controllable red, green, orange
• Direct activation Distance: 13 mm
• Activation distance through lexan / glass: 40 mm max.
• Electrical contact: 1 NO 400mA / 30V max.
• Contact operation: momentary action
• LED light control: 3 inputs PNP red, green, orange
• Fixing: drilling 48 mm F
• Drilling shoulder? F x 51 mm (wall thickness, 1.5 mm)
• Indexing: {predict notch pin 4.2 (L) x 3 (H) x 2 (l)}
• E Editing: Flush / pasted from behind
• Material: TR90UV
• Food environment: yes
• Ilieu pharmaceutical M: yes
• Cleanroom environment: yes
• Resistance to washing: yes
• Electrical connection: cable 7 x 0,25 / 10 cm (standard)
• É tanchéité: IP 67 with silicone seal
• Temperature: -25 ° C to +60 ° C
• Branding: screen printing on the back of the reference product