Cylindrical safety sensor M18
Position control for low-play doors / casings on hazardous machinery
Contactless coded electronic sensor
Total safety management with an AWAX controller
Cylindrical M18 for "invisible" assembly
Level of performance with AWAX controller: up to PL = e
Safety category: up to 4 with an AWAX controller
• Time before dangerous failure: MTTFd = 100 years
• Max. activation distance: 6 mm, 2 mm hysteresis
• Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xcontact PNP 250mA
• Detection encoding: mono-code inviolable
• Reset: automatic
• Attachment: 2 M30 nuts provided
• Mounting position: 1
• Material: INOX316L
• Electrical connection: M12 metal base
• Water resistance: IP 67
• Temperature: -20°C to +60°C
• Marking: label + serial no. for traceability