Gas and fluid pressure control
Redundant low and high pressure control with channel synchronization
Pressure control from 0.1b to 60b (to be defined when ordering)
Vacuum control from -0.2b to -0.9b (to be defined when ordering)
Level of performance with AWAX controller: up to PL = e
Level of performance only: PL = c
• Safety category with an external controller: up to 4
• 'Integrated security' level with an external controller: up to SIL 3
• C ycle before dangerous failure: B10d = 100,000
• Safety contacts: 2 x NO 2A/50V
• Auxiliary contact: 1 x PNP NF 2A/50V
• Reset: automatic
• Attachment: 4 x M4 flat head or domed screws
• Mounting position: 1
• Material: Polycarbonate
• Electrical connection: PUR UL20549 very durable 50 cm cord with M12 connector
• Pneumatic connection: G1/4 and 8 mm quick connector
• Water resistance: IP 65
• Ambient temperature: -25°C to +60°C
• Fluid temperature: -40°C to 140°C (specify temperature and the nature of the fluid in the order)
• Marking: label + serial no. for traceability