Introduction
Gasboard-3500UV is the new generation biogas monitoring system that primarily designed based on UV-DOAS technology to measure H2S concentration precisely before and after H2S scrubber, and extended with modular sensor of CH4 (NDIR), CO2(NDIR) and O2 (ECD) to realize online continuously monitoring of biogas quality without purging cycle required.The 2 sampling channels design before and after scrubber enable it to provide an ideal solution to guarantee the H2S scrubber efficiency, protect downstream expensive equipment from the damage of overload H2S, minimize the investment for users and optimize the biogas monitoring process.
Features
• Unique technology of UV-DOAS, NDIR and ECD combination.
• High & low range H2S measurement, switchable for points before and after scrubber.
• UV-DOAS H2S sensor with higher precision and longer lifespan.
• Continuous monitoring on H2S, CH4, CO2, O2 for optimized process control.
• Modular sensor design enables easy calibration and maintenance.
• Flexible gas conditioning configuration, customizable to site requirements.
• Stainless steel protective integration cabinet to avoid corrosion in long term operation.
• Ex-proof design applicable to outdoor hazardous area installation.
• Support up to 4 sampling channels
Specifications
Gas: H2S,CH4,CO2,O2
Technology: H2S: UV-DOAS;CH4:NDIR;CO2: NDIR;O2: ECD
Measurement Range: H2S: 0-500~5000ppm;CH4: 0-100%;CO2: 0-50%;O2: 0-25%
Resolution: H2S: 1ppm;CH4: 0.01%;CO2: 0.01%;O2: 0.01%
Accuracy: ±2%F.S.
Repeatability: ≤1%F.S.
Response Time: T90<60s
Gas Flow:(0.7~1.2) L/min
Gas Pressure:(2~50) kPa
Power Supply:AC220V, 100W
Ex-Proof Grade:ExdIICT6 (Analyzer)
Analog:4-20mA
Digital:RS232/485